Guppy PRO Technical Manual
V4.1.2
48
Absolute quantum efficiency (QE)
Standard accessories
Guppy PRO F-503B: Protection glass
Guppy PRO F-503C: IR cut filter
Optional accessories
Guppy PRO F-503B: IR cut filter, IR pass filter
Guppy PRO F-503C: Protection glass
On request
Host adapter card, power out 6 W (Hirose)
Software packages
https://www.alliedvision.com/en/support/software-downloads
Note
All measurements were done without protection glass or filter.
With protection glass or filters, quantum efficiency (QE)
decreases by approximately 10%.
The uncertainty in measurement of the QE values is
10.25%.
This is mainly due to uncertainties in the measuring apparatus
itself (Ulbricht sphere, optometer, etc.)
Manufacturing tolerance of the sensor increases overall
uncertainty.
Note
Sony provides relative response curves in their sensor data
sheets. To create the absolute QE and spectral response plots
shown in this chapter, the relative response was converted to
a normalized QE response and then adjusted as per three
measured QE values (@ 448 nm, 529 nm, 632 nm) for color
sensors and one measured QE value (@ 529 nm) for
monochrome sensors.
Note
Absolute QE plots for ON Semiconductor CMOS sensors
The curves in the absolute QE plots shown in this chapter are
from the sensor manufacturer data sheet.
The information was correct at the time of publishing. Sensor
specifications may change without notice.
Feature
Specification
Table 14: Guppy PRO F-503B, F-503C model specifications (continued)