Microcontroller sync is an internal signal. It is generated by the microcontroller
to initiate a trigger. This can either be a direct trigger or a release for ExSync if
the camera is externally triggered.
End of exposure to first packet on the bus
After the exposure, the CCD sensor is read out; some data is written into the
FRAME_BUFFER before being transmitted to the bus.
The time from the end of exposure to the start of transport on the bus is:
710 µs ± 62.5 µs
Feature
Value
One-shot
microcontroller sync
150 µs (processing time in the
microcontroller)
µC-Sync/ExSync
integration start
8 µs
Table 69: Values for one-shot