Mechanical dimensions
69
Mako G Technical Manual V4.2.2
Sensor position accuracy
Unless stated otherwise, the following values are applicable:
Figure 31: Allied Vision sensor position accuracy
Criteria
Subject
Properties
Alignment method
Optical alignment of photo sensitive sensor area into camera front
module (lens mount front flange).
Reference points
Sensor
Center of pixel area (photo sensitive cells)
Camera
Center of camera front flange (outer case edges)
Accuracy
x/y
±150 µm (sensor shift)
z
0 µm to -150 µm (optical back focal length)
α
±0.5° (sensor rotation as the deviation from the parallel to the
camera bottom)
Table 26: Sensor position accuracy criteria
x
y
Sensor case
ɲ
Camera body
Pixel area
Sensor case
Camera body
Pixel area