Triggering
90
Mako U Technical Manual V1.1.3
Digital I/O lines
Input path and TriggerSource
TriggerSource[TriggerSelector]
specifies the internal signal or
physical input line to use as trigger source.
To enable a trigger, its
TriggerMode[TriggerSelector]
must be set
to
On
.
TriggerSource values
Figure 38: Input block diagram
Signal
Description
Software
Specifies that the
TriggerSource[TriggerSelector]
will
be generated by software using the
TriggerSoftware
command.
Line0, Line1,
etc.
Specifies which physical line (or pin) and associated I/O control block
to use as external source for the trigger signal.
Table 41: Input path and TriggerSource values
Polarity
Selectable via
software
Strobe light
or
PC
or
Machine
LineStatus
Camera
Debouncer
CounterEventSource
TimerTrigger
EncoderSourceA
EncoderSourceB
TriggerSource