Camera interfaces
182
Manta Technical Manual V7.9.0
6
Out 1
Out
Open emitter,
maximum 10 mA
Opto-isolated output 1
(SyncOut1)
Green
7
Isolated In
GND
In/Out
---
Isolated input signal
ground
Brown
8
RxD RS232
In
RS232
Terminal receive data
White
9
TxD RS232
Out
RS232
Terminal transmit data
Black
10
Isolated Out
Power
In
Common VCC for outputs,
maximum 30 VDC
Power input for opto-
isolated outputs
Orange
11
In 2
In
Standard and PoE models:
U
in
(high) = 3 to 24 V
U
in
(low) = 0 to 1.0 V
Opto-isolated input 2
(SyncIn2)
White/Black
12
Out 2
Out
Open emitter,
maximum 10 mA
Opto-isolated output 2
(SyncOut2)
White/
Brown
Cable color and pin out
For cable color and pin out information, see the
Allied Vision I/O cable data sheet
:
https://www.alliedvision.com/en/support/technical-documentation/accessories-
data-sheets.html
Figure 108: Manta cable color coding
Camera side Hirose HR10- 10R-12PA(73) connector
I/O cable
color code
Pin
Signal
Direction
Level
Description
Table 81: Camera I/O connector pin assignment and Manta I/O cable color coding
i
Hirose HR10A
.
.
.
.
.
.
.
.
.
.
.
.
SHIELD
1
2
3
4
5
6
7
8
9
10
11
12
.
BLUE
RED
PINK
GREY
YELLOW
GREEN
BROWN
WHITE
BLACK
ORANGE
WHITE/BLACK
WHITE/BROWN
Open End
.
.
.
.
.
.
.
.
.
.
.
.
TRANSPARENT
.
.
.
.
.
.
.
.
.
.
.
.
.