Camera interfaces
183
Manta Technical Manual V7.9.0
Input block diagram
The inputs can be connected directly to the system for voltages up to 24 VDC. An
external resistor is not necessary.
Cycle delay
The cycle delay for all Manta cameras is tpdLH < 3.5 µs and tpdHL < 30 µs. For this
reason, we recommend to trigger on the rising edge. This guarantees a reaction
time that is as fast as possible.
Figure 109: Input block diagram
For customers who designed their system for Manta cameras with serial numbers
up to serial number 503323258, use your systems with an external resistor
without any restrictions.
Parameter
Value
U
in
(low)
0 to 1.0 V
U
in
(high)
3 to 24 V
Current (constant-current source)
3 to 4 mA
Table 82: Input parameters
In1
Isolated In GND
External Internal
In2
180R
180R