Specifications
60
Manta Technical Manual V7.9.0
Trigger latency
1
Idle state: 19.3 µs; Frame valid state: 45.2 µs
Idle state: 12.6 µs; Frame valid state: 25.6 µs (30 fps variants)
Trigger jitter
1
Idle state:
±
9.8 µs; Frame valid state:
±
35.7 µs
Idle state:
±
6.9 µs; Frame valid state:
±
19.9 µs (30 fps variants)
Body dimensions (L × W × H)
86.4 × 44 × 29
mm
Mass (typical)
PoE model: 210 g; Non-PoE model: 200 g
1
It is possible to start the exposure of the next frame while the previous frame is read out:
•
Idle state: sensor is ready and camera is idle, waiting for the next trigger
•
Frame valid state: sensor is reading out and camera is busy. If the next frame is requested by an external
trigger in this state, higher latency may occur as compared to the idle state.
Feature
Specification
Manta G-145B
Manta G-145C
Table 17: Manta G-145B, G-145C (including 30 fps variants) model specifications