Camera interfaces
184
Manta Technical Manual V7.9.0
Minimum pulse width
The minimum pulse width for all Manta cameras is:
Test conditions
The input signal was driven with 3.3 V and no external additional series resistor.
Output block diagram
Figure 110: Minimum pulse width
Figure 111: Output block diagram
•
Maximum 10 mA per output
•
Isolated out power > 30 V may damage the camera.
Isolated out power
Resistor value
1
5 V
1.0 k
at
5 mA minimum required
current draw
12 V
2.4 k
24 V
4.7 k
1
Resistor required if Out1/2 connected to a device with < 5 mA draw, i.e., high impedance.
Table 83: Isolated out power and external resistor
I
F
0
t
ϰϰʅƐ
ϲʅƐ
20 kHz
External
Internal
Isolated Out Power
Out1
Out2
R
R