Camera interfaces
66
Prosilica GC Technical Manual V2.2.0
Camera I/O non-isolated user circuit
example
The non-isolated trigger circuit is connected to a Texas Instruments SN74LVC2G241
buffer/driver inside the camera. See the Texas Instruments SN74LVC2G241 for
more detailed information.
Figure 29: Prosilica GC non-isolated user circuit
Input/Output
Input: Incoming trigger must be able to source 10 µA, at 3.3 V. Input trigger voltage
greater than 5.5 V will damage the camera.
Output: The maximum sync output current is 24 mA, at 3.3 V.
CAMERA GND
1
2
3
4
5
6
7
8
9
10
12
HIROSE HR10A-10P-12S
1
2
3
4
5
6
7
8
9
10
11
12
CABLE SIDE
11
12 V POWER
IN 2
OUT 2
CAMERA GND
CAMERA POWER
IN 2 (3.3 V DRIVER)
OUT 2 (3.3 V RECEIVER)