508219-01
Issue 2132
Page 16 of 43
•
Locate unit away from overhanging roof lines which
would allow water or ice to drop on, or in front of, coil
or into unit.
When outdoor unit is connected to factory-approved indoor
unit, outdoor unit contains system refrigerant charge for
operation with matching indoor unit when connected by 15
ft. of field-supplied tubing. For proper unit operation, check
refrigerant charge using charging information located on
control box cover.
Outdoor Section
Zoning ordinances may govern the minimum distance the
condensing unit can be installed from the property line.
Install on a Solid, Level Mounting Pad
The outdoor section is to be installed on a solid foundation.
This foundation should extend a minimum of 2” (inches)
beyond the sides of the outdoor section. To reduce the
possibility of noise transmission, the foundation slab
should NOT be in contact with or be an integral part of the
building foundation. See Figure 2.
If conditions or local codes require the unit be attached to
pad or mounting frame, tie down bolts should be used and
secured to unit base pan.
Refrigerant Metering Device - Indoor Coil
For correct metering device, refer to chart below.
Outdoor Model
Orifice Size
Indoor
Expansion
Device
Outdoor Model
Orifice Size
Indoor
Expansion
Device
4SCU14L*118P-7
0.053
A4TXV01
4SCU14LE118P-4
0.053
A4TXV01
4SCU14LBR18P-7
0.053
A4TXV01
4SCU14LE124P-4
0.057
A4TXV01
4SCU14L*124P-7
0.057
A4TXV01
4SCU14LE130P-4
0.065
A4TXV01
4SCU14LBR24P-7
0.057
A4TXV01
4SCU14LE136P-4
0.071
A4TXV01
4SCU14L*130P-7
0.065
A4TXV01
4SCU14LE141P-4
N/A
A4TXV02
4SCU14LBR30P-7
0.065
A4TXV01
4SCU14LE142P-4
N/A
A4TXV02
4SCU14L*136P-7
0.071
A4TXV01
4SCU14LE147P-4
N/A
A4TXV02
4SCU14LBR36P-7
0.071
A4TXV01
4SCU14LE148P-4
N/A
A4TXV02
4SCU14L*142P-7
N/A
A4TXV02
4SCU14LE159P-4
N/A
A4TXV02
4SCU14LBR42P-7
N/A
A4TXV02
4SCU14LE160P-4
N/A
A4TXV02
Table 1.
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
who have jurisdiction before installation.
Installation
NOTE:
In some cases, noise in the living area has been
traced to gas pulsations from improper installation of
equipment.
•
Locate unit away from windows, patios, decks, etc.
where unit operation sounds may disturb customer.
•
Leave some slack between structure and unit to
absorb vibration.
•
Place a sound-absorbing material, such as Isomode,
under the unit if it will be installed in a location or
position that will transmit sound or vibration to the
living area or adjacent buildings.
•
In heavy snow areas, do not locate the unit where
drifting snow will occur. The unit base should be
elevated above the depth of average snows.
NOTE:
Elevation of the unit may be accomplished
by constructing a frame using suitable materials. If a
support frame is constructed, it must not block drain
holes in unit base.
•
When installed in areas where low ambient
temperatures exist, locate unit so winter prevailing
winds do not blow directly into outdoor coil.
Summary of Contents for 4SCU14LB
Page 34: ...508219 01 Issue 2132 Page 34 of 43 Wiring Diagram Figure 13 A C Single Phase Wiring Diagram ...
Page 35: ...508219 01 Issue 2132 Page 35 of 43 Figure 14 A C Single Phase Wiring Diagram 59 model only ...
Page 36: ...508219 01 Issue 2132 Page 36 of 43 Figure 15 3 Phase 208 230 Volt ...
Page 37: ...508219 01 Issue 2132 Page 37 of 43 Figure 16 3 Phase 460 Volt ...
Page 41: ...508219 01 Issue 2132 Page 41 of 43 Charge Labels Figure 17 4SCU16LE 4SCU14LB 50 ...
Page 42: ...508219 01 Issue 2132 Page 42 of 43 Figure 18 4SCU14LE LB 4 thru 7 ...