508142-01
Issue 2047
Page 2 of 33
Technical Specifications - A80DF1E
MODEL NUMBER GUIDE
Numeric Code
12 = 3 Ton add on cooling
16 = 4 Ton add on cooling
20 = 5 Ton add on cooling
A = 14.5" Width
B = 17.5 Width
C = 21.0 Width
D = 24.5 Width
A = Flagship
80 = 80% Efficiency
UH = Upflow/Horizontal
DF = Downflow
1 = 1 Stage
E = High Efficency Motor
Heating Input x 1000
A 80 DF 1 E 110 C 20 01
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nom.
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Downflow
A80DF1E045A12
44,000
36,000
80.00%
2 — 3
1/2
120-60-1
15
6.8
40
113
A80DF1E070A12
66,000
54,000
80.00%
2 — 3
1/2
120-60-1
15
6.8
40
119
A80DF1E070B12
66,000
54,000
80.00%
2 — 3
1/2
120-60-1
15
6.8
40
128
A80DF1E090B16
88,000
72,000
80.00%
3 — 4
1/2
120-60-1
15
8.4
40
140
A80DF1E110C20 110,000
90,000
80.00%
4 — 5
1/2
120-60-1
15
10.9
40
160
Note: For vent sizing and clearances to combustibles, please reference installation instructions.