508093-01
Issue 2033
Page 2 of 59
Technical Specifications - A95UH1E
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nominal
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Upflow/Horizontal
A95UH1E030B08S
30,000
28,000
95%
1-1/2 — 3
1/2
120 - 60 - 1
15
6.8
40
129
A95UH1E045B12S
44,000
42,000
95%
1-1/2 — 3
1/2
120 - 60 - 1
15
6.8
40
129
A95UH1E070B12S
66,000
64,000
95%
1-1/2 — 3
1/2
120 - 60 - 1
15
6.8
40
136
A95UH1E090C16S
88,000
85,000
95%
2-1/2— 4
1/2
120 - 60 - 1
15
8.4
40
160
A95UH1E110C20S
110,000
106,000
95%
3 — 5
1/2
120 - 60 - 1
15
10.9
40
170
A95UH1E135D20S
132,000
128,000
95%
3-1/2 — 5
1/2
120 - 60 - 1
15
10.9
40
187
Note: For vent length and clearances to combustibles, please reference installation instructions.
MODEL NUMBER GUIDE
Numeric Code
S = Stainless Steel Heat Exchanger
08 = 2 ton add on cooling
12 = 3 Ton add on cooling
16 = 4 Ton add on cooling
20 = 5 Ton add on cooling
B = 17.5 Width
C = 21.0 Width
D = 24.5 Width
A = Flagship
95 = 95% Efficiency
UH = Upflow/Horizontal
DF = Downflow
1 = 1 Stage
E = High Efficiency Motor
Heating Input x 1000
A 95 UH 1 E 110 C 20 S - 01