507962-01
Page 18 of 53
Issue 2149
96G2DFV Maximum Allowable Intake or Exhaust Vent Length in Feet
Standard Termination at Elevation 0 - 4,500 ft
Number of
90° Elbows
Used
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3" Pipe
Capacity
Capacity
Capacity
Capacity
070
090
110
070
090
110
070
090
110
070
090
110
1
15
n/a
n/a
51
29
9
100
78
43
122
103
103
2
10
46
24
n/a
95
73
38
117
98
98
3
n/a
41
19
90
68
33
112
93
93
4
36
14
85
63
28
107
88
88
5
31
9
80
58
23
102
83
83
6
26
n/a
75
53
18
97
78
78
7
21
70
48
13
92
73
73
8
16
65
43
8
87
68
68
9
11
60
38
n/a
82
63
63
10
6
55
33
77
58
58
Standard Termination at Elevation 4,501 - 10,000 ft
Number of
90° Elbows
Used
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3" Pipe
Capacity
Capacity
Capacity
Capacity
070
090
110
070
090
110
070
090
110
070
090
110
1
15
n/a
n/a
51
29
n/a
100
78
43
122
103
103
2
10
46
24
95
73
38
117
98
98
3
n/a
41
19
90
68
33
112
93
93
4
36
14
85
63
28
107
88
88
5
31
9
80
58
23
102
83
83
6
26
n/a
75
53
18
97
78
78
7
21
70
48
13
92
73
73
8
16
65
43
8
87
68
68
9
11
60
38
n/a
82
63
63
10
n/a
55
33
77
58
58
*Size intake and exhaust pipe length separately. Values in table are for intake OR Exhaust, not combined total. Both Intake and
Exhaust must be same pipe size.
Table 7A.
Table 7.