507962-01
Page 48 of 53
Issue 2149
Model
Temp Rise
Speed
Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
96G2DF090CV20
High Fire
35 - 65
+
1395
1555
1695
1825
Normal
1275
1395
1585
1670
-
1145
1265
1405
1525
Low Fire
20 - 50
+
1130
1230
1365
1475
Normal
1040
1130
1250
1340
-
910
1025
1130
1210
Cooling
Stage
Speed
Adjustment
Cooling CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
2nd Stage
+
1335
1600
1750
1980
Normal
1225
1450
1630
1830
-
1120
1270
1450
1660
1st Stage
+
955
1115
1265
1450
Normal
855
1005
1150
1285
-
750
890
1060
1170
Model
Temp Rise
Speed
Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
96G2DF110CV20
High Fire
35 - 65
+
1595
1795
1955
2140
Normal
1450
1615
1795
1975
-
1290
1460
1610
1795
Low Fire
25 - 55
+
1165
1305
1465
1625
Normal
1055
1185
1315
1475
-
930
1070
1180
1320
Cooling
Stage
Speed
Adjustment
Cooling CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
2nd Stage
+
1335
1585
1790
2010
Normal
1220
1440
1630
1865
-
1100
1275
1475
1680
1st Stage
+
920
1095
1265
1440
Normal
830
965
1130
1290
-
735
860
1035
1155