SECTION 8.0
INSTALLATION & REMOVAL
8.1 Installation
~WARNING~
Always wear gloves and eye protection
when connecting hydraulic connections,
and installing mounting pins and
hardware.
~
CAUTION
~
Mount only on carriers with adequate
lift and hydraulic capacity. Under no
circumstances shall the oil pressure
supplied to the Ho-Pac exceed 2200 psi
(138 bar)
~
CAUTION
~
The Ho-pac hydraulic return line must
be open to tank. Hydraulic motor
damage results if the return line is
suddenly closed by incorrect hydraulic
circuitry.
1. Prior to installation, carefully
inspect:
a. Spring mounts for cracks and
other damage.
b. Hoses and fittings for damage.
c. Threaded fasteners, boom pins,
and mounting hardware for
damage.
2. Repair or replace any damaged
components.
3. Follow hydraulic and mounting kit
installation instructions.
~
WARNING
~
Keep hands and fingers clear of
mounting pin holes, carrier linkage and
other pinch points while equipment is
being positioned.
~
CAUTION
~
During installation, instruct carrier
operator to operate carrier controls only
as instructed by Ho-Pac installer.
~
CAUTION
~
Never install hydraulic hoses inside the
operators cab.
4. After installation and prior to use,
briefly operate the Ho-Pac, then stop
the Ho-Pac and re-check the
following:
a. Hydraulic hoses and fittings for
leaks.
b. Mounting hardware for loose or
missing parts.
c. Bolt torques. See Section 11.6.
19
7/21/03
Summary of Contents for Ho-Pac NT8900 Series
Page 1: ......
Page 2: ...Allied Ho Pac Model NT8900 Series Document Change Notice ...
Page 34: ...This Page Intentionally Left Blank 7 21 03 30 ...
Page 38: ...8 1 2 3 16 7 13 14 15 14 11 6 5 9 10 12 5 4 VMS V10 Mounting Frame Ho Pac 7 21 03 34 ...
Page 40: ...5 8 9 2 7 10 6 Custom Flat Top Mounting Frame Ho Pac 7 21 03 36 ...
Page 42: ...5 4 1 1 7 14 6 3 2 11 10 15 8 12 8 13 9 BCS Mounting Frame Ho Pac 7 21 03 38 ...
Page 45: ...This Page Intentionally Left Blank 41 7 21 03 ...
Page 46: ......