SECTION 10.0
TROUBLESHOOTING
Listed below are several operating
problems and their recommended
corrective action.
1.
Unit does not run:
a. Insufficient oil pressure or flow.
Check hydraulic supply system.
Correct
as
required.
b. Failed bearings. Inspect and re-
place bearings.
c. Broken motor shaft or worn
splines. Inspect and replace
worn parts.
2. Unit
runs
erratically:
a. Erratic oil pressure or flow.
Check hydraulic supply system.
Correct as required.
b. Failed spring mount. Inspect
and replace failed mount.
3.
Unit runs with excessive noise or
vibration:
a. Loose bolts or mounting
hardware. Inspect and tighten
bolts.
b. Failed bearing. Inspect and
replace bearings.
4.
Unit runs, but stalls under load:
a. Pressure relief too low. Check
hydraulic supply system. Correct
as required.
b. Failed bearing. Inspect and
replace bearings.
c. Motor worn or motor seals
failed. Inspect and replace
motor.
For conditions other than these, contact
the Allied Technical Service Depart-
ment.