Page 1: ...00 50 PSI Air Compressor Operator s IVIanual Cautifin Federal law restricts this device to sale by or on order of a physician or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device ...

Page 2: ...ides Information necessary to operate the Schuco Model S6000 50 PSI Compressor This unit is designed for efficient continuous high pressure performance The Model S6000 Compressor provides high pressure which clinical studies have Indicated are required for optimal particle size 2 microns or less during nebulization treatments The unit operates quietly and effectively due to the unique design ofthe...

Page 3: ...TION Information for preventing damage to the product A NOTE Information to which you should pay special attention READ THE ENTIRE OPERATOR S MANUAL BEFORE USING SAVE THIS OPERATOR S MANUAL A Note Connect power cord and plug into properly grounded wall outlet or adapter A Note Unplug the power cord when it is necessary to disconnect AC power source A Note The Schuco S6000 compressor is not designe...

Page 4: ...es pressure REGULATOR Determines Pressure output iNTAKE RLTER HANDLE POWER CORD ON OFF SWiTCH Starts and stops unit PROTECTIVE COVER FIGURE 1 COMPRESSED AiR OUTLET Shown with L Bracket attached POWER RESET Resets circuit breaker should overload occur ...

Page 5: ...n that all connections to outlet i e tubing nebulizers etc are snug and not leaking aerosol 6 When used in conjunction with mist tents etc place the unit outside of the tent and position the unit at a level below the discharge end of the delivery tubing OPERATION 1 Press the Power On Off switch to ON position figure 1 2 Connect the equipment you intend to use with the Schuco IVIodel S6000 compress...

Page 6: ...one when dirty Do not wash it Replacement Air Filter Par S66 012 Pack of 5 CLEANING THE COMPRESSOR HOUSING Q OOO The compressor housing may be cleaned after the unit is unplugged by wiping the unit down with a damp cloth or cleaning wipe containing household cleaner or disinfectant Do not spray or drip any liquids directly onto the compressor FIGURE 2 ...

Page 7: ...ower Consumption watts 0 PSI 170 Operating Temperature range 50 F 104 F 10 40 C Operating Relative Humiditv 95 Storage Transport Temperature Relative Range room condition preferred Circuit Breaker 5A 125 250 V A C Eouipment Classifications Electrical shock Class 1 1 Electrical hazard protection class Type B No AP APG Eguipment not suitable for use in the presence of a flammable anaesthetic mixture...

Page 8: ...r source fuse in hoOse B Limited air flow 1 Faulty Delivery Tubing 2 Leak Blocked intake filter 1 Disconnect delivery tubing at outlet If proper flow is restored check equipment and tubing for obstructions or kinks Replace if needed 2 Check fitting at outlet and tubing 3 Replace air intake filter C All other problems 1 Allied Healthcare products Inc Symbols UL 60601 1 Table Dl IEC symbols Symbol I...

Page 9: ...AND FITNESS FORAPARTICULAR PURPOSE ARE DISCLAIMED Some states do not allow limitations on how long an implied warranty lasts so tlie above limitations may not apply The sole and exclusive remedy under this warranty is to repair or replace this COMPRESSOR and or its parts at fte option of AUied IN NO EVENT SHALL ALLIED BE LIABLE FOR INCroENTAL OR CONSEQUENTIAL DAMAGES TO THE PURCHASER OR ANY THIRD ...

Page 10: ...ags of 3 S6000 904 Gauge S6000 905 A d a p t e r A s s e m b l y 36000 906 On Off S w i t c h S6000 907 c i r c u i t B r e a k e r S6000 908 C a p a c i t o r 17uf 250VAC S6000 909 F r o n t Cover S6000 910 M o u n t i n g B l a c k Adapter S6000 911 Power C o r d 115V 50 60Hz S6000 912 Rubber Pad Need to come in bags of 4 S6000 913 Handle ...