Not for
Reproduction
21
Stopping the Compressor
1. Close the service valve completely and operate
the machine about 5 minutes, until it cools down.
2. Turn the starter switch to STOP position to stop
the engine.
3. Remove the key from the compressor every time
you stop the engine. Keep the key and be careful
not to lose it.
• Unless all service valves are fully closed upon
stopping operation, the compressed air will be
sent in reverse direction in the hoses (pipes)
connected to air tools and relieved to atmosphere
continuously through the auto-relief valve. When
re-starting operation next time, compressed air
will be jetted out through service valves.
Air Bleeding in Fuel Line
Should the machine stop due to fuel shortage, perform
air bleeding according to the following
• Replenish fuel.
• When starter switch is turned to RUN position,
electromagnetic pump starts to automatically
bleed air in fuel line.
• Air bleeding is completed about 1 minute.
DPF (Diesel Particulate Filter)
Regeneration (Purge)
WARNING
• During DPF regeneration operation, exhaust gas of
high temperature is discharged. Check and confirm
that there are no persons or flammables near by.
Exhaust gases could cause severe burns, and could
result in a fire.
•
During regeneration operation in closed spaces,
carefully monitor carbon monoxide levels to avoid
carbon monoxide poisoning.
When regeneration control is begun and finished,
noise of engine air intake throttle and EGR opening
width adjustment is sometimes caused. This is normal.
The smell of the exhaust gas caused during
regeneration operation is different from that of diesel
fuel exhaust.
Passive Regeneration
Soot collected in the DPF is burnt automatically
because of high temperature during normal operation
under heavy load application.
Active (Automatic) Regeneration
• Operation under light load application or no load
requires active regeneration, because engine
exhaust temperature is not high enough to burn soot
collected in the DPF.
• During active regeneration mode operation, it is
possible to continue servicing job.
Active Regeneration Mode
1. Cleaning exhaust filter lamp (
A
) turns ON.
2. The regeneration process will last for about 30
minutes.
3. The lamp will turn OFF when regeneration is
complete.
Note:
Time required for regeneration depends on
load factor and ambient temperature.
NOTICE
• Do not stop engine during active regeneration
operation, except for unavoidable conditions.
A
Summary of Contents for 185 CFM
Page 8: ...N o t f o r R e p r o d u c t i o n 8 ALLMAND COM L B C F A K G E D J H I N M ...
Page 35: ...N o t f o r R e p r o d u c t i o n 35 Data Adjustment Procedure ...
Page 37: ...N o t f o r R e p r o d u c t i o n 37 ...
Page 38: ...N o t f o r R e p r o d u c t i o n 38 ALLMAND COM ...
Page 39: ...N o t f o r R e p r o d u c t i o n 39 Wiring Diagram ...
Page 41: ...N o t f o r R e p r o d u c t i o n 41 Air Piping Compressor Oil Piping ...