18 / 36 - English
6-1622396 - rev. 3 - 21/09/2021
Description:
A. Terminal block accessories input and output
B. Radio Module
C. Antenna terminal block
D. J1 - Connector for plug-in led control board
E. J2 - Connector for battery charger card
F. J3 - Connector for external radio memory
G. Inputs and Securities Dip Switch
H. Display and buttons
I. Fuse1 - 10A fuse for motor protection
J. Fuse2 - 2,5A fuse for accessories protection
K. Fuse - 2,5A fuse
WARNING!
Please note that
PH3
and
S3
inputs are
exclusively
dedicated to the “presence sensor” (the photocell and the magnetic loop that
is close to the automation) and cannot be used for other types of intervention. Like the STOP input, PH3 and S3 are both NORMALLY
CLOSED inputs, so the control unit interrupts its normal operation if at least one of these contacts is open.
1
LED RADIO
FUSE 1
FUSE 2
J2
J1
J3
2
3
4
5
6
7
8
9 10
11 12 13 14 15 16 17
20 21
LED STATUS
LED STATUS
J4
N
PE
L
230V 50Hz
FUSE
TRANSFORMER
230V / 23V 50Hz
TX
RX
GND
+ 24V
TX
+24V
FLASHING LAMP
24Vac 25W
24V
M
STOP DRY
CONTACT N.C.
LOOP
S3
NC contact
A
G
H
E
C
D
F
K
J
I
A
B
8. INSTALLATION OF ACCESSORIES TO THE CONTROL UNIT
Loop
Detector
Summary of Contents for 12007336
Page 15: ...Italiano 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Page 51: ...English 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Page 87: ...Fran ais 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Page 123: ...Espa ol 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Page 159: ...Nederlandse 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...