13
6-1624831 REV. 07 DEL 26/05/15
G
B
Tube for water drain
Tube for electric cables
Tube for electric cables
Tube for water drain
64 mm
64 mm
5
6
GATE STOPS FOR OPEN AND CLOSE POSITIONS
For the open position, adjust by turning the relative hexagonal cam
“1”
to one of its six
possible positions; lock with screw
“2”
.
For the close position, adjust to the best position by tightening or loosening the relative
bolt
“3”
EMERGENCY RELEASE
To be carried out after having disconnected the power supply to the motor.
In order to carry out the manual operation of the gate leaf the followings must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for the operator;
- That the physical effort necessary to move the gate leaf should not be higher than 225
N, for doors/gates for private dwellings, and, 390N for doors/gates for commercial and
industrial sites ( values indicated in 5.3.5 of the EN 12453 norm) .
In the case of a power cut, the gate can be opened manually by releasing the lock on the
operating lever to allow the gate to move freely.
ELECTRICAL SAFETY DEVICES
The installation must be installed according to the current regulations and laws.
For connections and technical data of accessories refer to the appropriate booklets.
MAINTENANCE
To be undertaken by specialized staff after disconnecting power supply.
Make certain that moving parts located inside the box are greased once a year, and check
the force transmitted through the drive to the gate.
In the event that the need for servicing or repairs should arise, the speed reducer can be
removed from the box without taking down the gate.
- Lift the cover from the box, isolate the motor from the power supply by disconnecting the
cable, then remove the curved lever: the gate can now swing freely.
- Then unscrew the for nuts that fix the motor.
ELECTRICAL CONNECTIONS
BLU
=> NEUTRAL
BLACK
=> PHASE 1
GREY
=> PHASE 2
2
1
3
7
INTR/XL 110°
INTR/XL 360°
WARNING: NO WARRANTY WILL BE GARANTED IF
ELECTRICAL WIRE HAVE BEEN CUT.
ENSURE THAT THE CABLE JOINTS ARE MADE inside
a sealed junction box OUTSIDE THE INTR/XL BOX (the
junction box can be built-in to the wall or surface
mounted, positioned at a safe height of 40 cm and
must comply with the relevant standards).
Ensure that the water drainage is appropriate,
otherwise the penalty is the LOSS OF EACH
WARRANTY!