DIP SWITCH FUNCTIONS
TIMER
RADIO
OSC
TIMER
ON
RADIO
ON
OSC
ON
switch “
” activates the TIMER. See page 21
for details
switch “
” allows the radio receiver to override
the timer. See page 21 for details.
switch “
” allows the radio receiver to top and
reverse the gate n any direction.
signal stops gate,
second signal
gate.
.
s
i
During a cycle the first
a
reverses
FAIL SF/SC
1-PASS
SLAVE
AUTO OPEN
OPEN L/R
This is to set the operator as fail-safe or fail secure.
for
on power failure,
board will monitor battery voltage to make sure gate opens before battery drains out
completely.
for
on power failure gate will run until battery is low and
stay close.
This is a true one pass anti-tailgating feature. This feature may only be used with safety
loops. With this switch in the “
” position, the gate will open until one car passes the
safety loops then it will stop and close. If a second car pulls on the loop the gate will stop
the car must then back off the loop before the gate will close.
This feature is used on master/slave setups. Set slave switch “
” on slave machine, all
other switches “
”. Set slave switch to the “OFF” position on master machine. Set
other function switches on master machine as desired. See page
for more details on
master/slave connections and settings.
This feature is to
open the gate on power interruption. It is a very particular
feature used in areas where the fire department requires the gate to open automatically
after a power outage. Set this dip switch “ON” when this feature is desire.
This feature is to set the direction the operator will open. See page 8 for details.
ON
Fail-safe:
OFF
Fail-secure:
,
ON
ON
OFF
17
automatic
OFF ON
1 2 3 4 5 6 7 8
-----------------------OPEN------------------------
TIMER
RADIO
OSC
FAIL SF/SC
1-PASS
SLAVE
AUTO OPEN
OPEN L/R