LED DIAGNOSTICS
AC/PWR ON:
M/S LINK:
ALARM:
LOW BATTERY:
OPEN-LIMIT:
CLOSE-LIMIT:
OPENING:
CLOSING:
RADIO:
EXIT:
PHANTOM:
SAFETY:
PED-SW:
3BT:
EDGE:
TIMER LED:
CHRG:
Will be lit when AC power is ON.
Will be lit when master/slave communication is active.
Two states.
1st state: LED will blink(horn will beep also) every 30 seconds when battery is low, bad or
disconnected.
2nd state: LED will turn on for 5 minutes when operator goes on shut down mode do to the
gate hitting an obstruction(E.R.D.). Also, the horn will go off for 5 minutes.
Three states.
1st state: LED will be on solid when battery is low.
2nd state: LED will blink slow(about every 2 seconds) when an overload occurs(over
current).
3rd state: Will blink fast(abouty every ½ second) when gate is jammed or motor sensors
Are not responding or disconnected.
LED will be on while limit nut is against open limit switch.
LED will be on while limit nut is against close limit switch.
LED will be on while operator is in the open cycle(running open).
LED will be on while operator is in the close cycle(running close).
LED will turn on while radio input is activated(
to COMMON).
LED will turn on while EXIT input is activated
.
LED will turn on while PHANTOM input is activated
.
LED will turn on while SAFETY input is activated(circuit is open from COMMON).
LED will turn on while PED-SW input is activated(circuit is open from COMMON).
LED will turn on while 3BT input is activated(closed circuit to COMMON).
LED will turn on while EDGE input is activated(closed circuit to COMMON).
LED will blink when timer is counting (on the open position only).
LED turns on when battery is charging.
closed circuit
(closed circuit to COMMON)
(closed circuit to COMMON)
30