OPERATOR AND ARM DIMENTIONS
Note
: The 2” distance shown above is from the gate in the open position to the edge of the pad.
If the gate must open more than 90 degrees, the pad needs to move back accordingly. The
distance between the open gate and the pad needs to remain 2”. The distance “C” also needs to
move back accordingly if the opening is more than 90 degrees.
A
B
C
Minimum distance
: Is the distance between the gate bracket and the gate
hinge point.
: Is the distance between the gate hinge point and the edge
of the concrete pad.
: Is the distance from the gate in the open position to the center
shaft of the operator.
: Is the minimum distance required behind
the open gate. If the distance between the
open gate and the back wall is between 20”
and 33” refer to compact installation.
7
2”
B
OUTSIDE
INSIDE
POST
CONCRETE PAD
Minimum
distance
Dimentions Chart
Gate
length
A
B
C
Minimum
Distance
Less than
12”
13’-15’
16’-22’’
36”
37”
34”
40”
35”
42”
14”
14”
14”
41”
48”
47”
This distance is from
the gate in open
position to edge of the
pad. Refer to
.
note
A
C
PRIMAR
Y
SECONDAR
Y
HINGE
CENTER
Refer to
below.