background image

 

BWS-136 User Manual_amend.doc

 

- 11 -

 

 

Serial Port Pin Assignments 

Serial Port COM1 uses a Male DB9 connector and it includes 

RS-232, RS-422 and RS485 signal and pin assignments are 

described as follow: 

 

 

 

Transmission Signals 

Pin 

Number 

RS-232 4-wire 

RS485 

RS-485 

1 DCD 

TxD- - 

2 RxD 

TxD+ 

3 TxD 

RxD+ 

Data+ 

4 DTR 

RxD- 

Data- 

5 GND 

GND 

GND 

6 DSR  -  - 

7 RTS -  - 

8 CTS -  - 

9 - - - 

 

 

BWS-136 User Manual_amend.doc

 

- 12 -

 

 

Digital I/O 

Digital I/O uses DB9 connector and the pin assignments 

are described as follow

 

Pin 1: DIO4 

Pin 2: DIO3 

Pin 3: DIO2 

Pin 4: DIO1 

Pin 5: DIO0 

Pin 6: GND 

Pin 7: DIO7 

Pin 8: DIO6 

Pin 9: DIO5 

 

DIO0 to DIO5 are TTL compatible Programmable 

DIO and DIO 6 to DIO7 are CMOS compatible Programmable DIO. 

All the DIO channel are pull up +5VDC with a 4.7K Ohm resistor. 

 

As an Output

DIO

GND

As an Input

DIO

GND

 

 

Summary of Contents for Network Device BWS-136

Page 1: ...ut 7 Connecting Power 7 Connecting Ethernet Port 8 Connecting Serial Port 8 Switch SW1 Settings 8 LED Status 10 Serial Port Pin Assignments 11 Factory Default Settings 13 Configure BWS 136 14 Install...

Page 2: ...g capability BWS 136 converts the serial data to standard TCP IP protocol therefore the serial device can be accessed everywhere via Internet or Ethernet In addition BWS 136 provides an embedded Web s...

Page 3: ...SD Digital Input Output General Purpose DIO x8 DIO0 to DIO5 Programmable Digital I O TTL DIO6 to DIO7 Programmable Digital I O CMOS BWS 136 User Manual_amend doc 6 Software Protocol TCP IP HTTP ICMP D...

Page 4: ...to the Ethernet port of BWS 136 The Link Activity light will keep solid yellow color if Ethernet cable is corrected to the network and this light will keep flashing if there are data transmitted Conn...

Page 5: ...s The LED provides the BWS 136 operation information The LED status is described as follow Power LED Power LED keeps ON if power 9VDC to 40VDC is correctly input to BWS 136 Ready LED Ready LED keeps O...

Page 6: ...Data 4 DTR RxD Data 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 BWS 136 User Manual_amend doc 12 Digital I O Digital I O uses DB9 connector and the pin assignments are described as follow Pin 1 DIO4 Pin 2 DIO3...

Page 7: ...Data Format N 8 1 Parity Data bits Stop bits Flow Control None Interface RS 232 BWS 136 User Manual_amend doc 14 Configure BWS 136 Aport 211 provides four ways to configure the settings They are 1 Ja...

Page 8: ...address of the module you can click Search by IP item and specify the IP address to find the BWS 136 User Manual_amend doc 16 BWS 136 The default IP address of BWS 136 is 192 168 16 10 Click on the r...

Page 9: ...IP Address TCP port and operation mode as follow OpMode TCP operation mode setting TCP Port TCP Port number of BWS 136 Destination IP The IP address of remote host which BWS 136 will actively connect...

Page 10: ...on Pages in the next entry BWS 136 User Manual_amend doc 20 Save Configuration After the all the settings are configured click to the Save to Module button to save the settings to the module The new s...

Page 11: ...BWS 136 by using the Import button BWS 136 User Manual_amend doc 22 4 Web Configuration Overview BWS 136 can also be configured by Web Browser The build in Web server and Web configuration pages makes...

Page 12: ...nd doc 24 Customize Your Web Page After you complete your web page design you can use the Manager Utility manager jar to upload the Web page to bws 136 Web server The web files need to be converted to...

Page 13: ...er can use serial terminal or Telnet command to configure BWS 136 when Web browser and Java utility are available In addition these functions provide user the most convenient way to develop their own...

Page 14: ...nd format is as follow LOG 16 bytes of TEA Encrypted Password or LOG if there are no password settings BWS 136 User Manual_amend doc 28 Forgot Password If you forgot the Password you can switch SW1 to...

Page 15: ...136 User Manual_amend doc 30 RS 422 RS 485 G S LI IP Address e g SLI192 168 2 127 G S LN Netmask e g SLN255 0 0 0 G S LG Gateway e g SLG192 168 2 254 G S LC IP Mode 0 Static IP 1 DCHP G LM MAC Defaul...

Page 16: ...etting as Default setting System S EI Exit console DIO S DM Set Digital I O mode I Input O Output H pull high L pull low BWS 136 User Manual_amend doc 32 e g SDMI 0 4 5 set DIO0 DIO4 DIO5 as input SDM...

Page 17: ...dham of the Cambridge Computer Laboratory Placed in the Public Domain by David Wheeler and Roger Needham ANSI C VERSION New Variant Notes TEA is a Feistel cipher with XOR and addition as the non linea...

Page 18: ...igned long const v unsigned long const w const unsigned long const k register unsigned long y v 0 z v 1 sum 0xC6EF3720 delta 0x9E3779B9 n 32 sum delta 5 in general sum delta n while n 0 z y 4 y 5 y su...

Reviews: