9. Cable Distances and Limitations
-
TP Cable Limitations:
Cat 5 up to 100m
-
Fibre Cable Limitations:
Mode
Multi-Mode Fibre
62.5/125μm
Multi-Mode Fibre
50/125μm
Bandwidth
MHz-Km
Distance
Bandwidth
MHz-Km
Distance
1000SX (SC/LC)
850nm
160
220m
400
500m
200
275m
500
550m
1000LX (SC/LC)
1310nm/
1550nm
Single Mode Fibre 9/125
μm
Single Mode transceiver 1310nm: 10Km
Single Mode transceiver 1550nm: 30/50Km
10. Technical Specifications
Standards
:
IEEE802.3u 10/100Base-TX, 100Base-FX
IEEE802
.
3z/ab 1000Base-T
IEEE802.3af Power over Ethernet
UTP Cable
:
Cat. 5 cable and up to100m
Fibre Cable
:
50/125, 62.5/125 or 100/140
m multi-mode
8.3/125, 8.7/125, 9/125 or 10/125
m single-mode
PSE Power Feeding Supports :
―Endpoint‖ via TP pin 1, 2, 3, 6
LED Indicators :
POWER, PoE, TP LNK/ACT, SPD, FX LNK/ACT, 4W,7W,15.4W
Data Transfer Rate :
Speed
Forwarding Rate
1000Mbps
148,8000 PPS
100Mbps
148,800 PPS
10Mbps
14,880 PPS
Flow Control :
IEEE802.3x compliant for full duplex
Backpressure flow control for half duplex
Power Requirement :
AC Line:
100-240V 50-60Hz
Power Consumption :
24W
Ambient Temperature :
0
to 50
C
Humidity :
5% to 90%
Dimensions :
40(H)
158(W)
133(D) mm
Complies with C-Tick, FCC Part 15 Class A and CE Mark