2. 

Unplug the power cord from the mains.

 

 

3. 

Remove the hose adapter by lifting the hose adapter securing buckle and pulling 

the adapter out of the motor head.

 

 

4. 

Holding the canister at the base, move it to a 

flat stable surface near a sink or other 

drain. (Be sure to hold upright to avoid spillages.)

 

 

5. 

To open the unit, unfasten the 2 buckles that are situated at the front and back of the 

filter then lift the 2 levers that are attached to the left and right sides of the motor head. On 
doing this the motor head will lift away from the unit. Set aside.

 

 

6. 

Holding the media baskets in place, tilt the canister over the sink or drain, and pour out 

as much water as possible.

 

 

7. 

Your media and foams will be saturated with water. Lift the 

filter media baskets 

out of the canister and place them in your sink or a large bucket.

 

 

8. 

Rinse the inside of the canister with clear aquarium water. NEVER use tap water, or 

soap or detergents, when cleaning your unit or rinsing media.

 

 

9. 

Rinse the inside of the priming cylinder with clear aquarium water. Make sure no debris 

is trapped inside the cylinder.

 

10. 

When you are ready to reconnect your 

filter, reinsert the filter media trays and 

reposition beneath your aquarium. Before replacing the motor head on the 

filter, fill your 

filter 3/4 full with water from your aquarium. Place the motor head back on top of the unit, 
shut both of the motor head levers down and fasten the buckles to the side of the 

filter. Fit 

the hose adapter back into the motor head and re-fasten it using the securing buckle.

 

11. 

Top up your aquarium tank water level from any water used.

 

12. 

Reconnect the power cord to the mains.

 

Summary of Contents for EF1+

Page 1: ...ON AQUARIUM EXTERNALFILTERS EF1 EF2 EFX BUILT IN UV CLARIFICATI EASY PRIMING SYSTEM MULTI LAYER FILTRATION TAP SHUT OFF SYSTEM QUIET OPERATION EASY TO MAINTAIN...

Page 2: ...ated This lterissuitableforindoorhouseholdaquariumsonly donotusein exterior locations swimmingpools ponds bathroomsetc Donotplacein liquids other than water Do not use with water above 90 F or 30 C Do...

Page 3: ...eryoupurchasedthisunitfromfor further advice Ifthe plug orunit does getwet DON Tunplug the cord First disconnect thecircuit breakerorfusethatsuppliespowertotheappliance Next unplug and inspect forwate...

Page 4: ...T LINEfrom the ltertotherimoftheaquarium Ifthehosingistoolongthe lterWILL NOT WORK CORRECTLY Theinlet pipe should NOTbepositioned tooclose to an airstone aeration device or theoutputvalvetoavoidreduci...

Page 5: ...sshuttoavoidleakage leverdown andensureyour pipework is setup as per the Set Up Diagram Fityourhose toyouraquarium soas theinlet hose is tted tothe over owpipe andthe outlethoseis ttedtothespraybarasp...

Page 6: ...iltheoutput hose has lledwithwater You are now ready to plug your external lter in IMPORTANT topreventanydamagetoyouunit ensurethecanisteris completelyfull ofwater before the unit is switched on Water...

Page 7: ...oyourunitand may invalidate your warranty Werecommend that a regularcleaning and maintenance schedule is followed to ensure responsible shkeeping Dependingonwatervolumeandstockinglevels regularcleanin...

Page 8: ...nd ltermediamonthly Pipeworkwillbecome blockedwithwaste andproteinslime overtime soregularcleaningisimportantforoptimal performance Thefrequencyofhowoftenyouwillneedtocleanandinspectyourunitof coursew...

Page 9: ...through an impeller guardinthemiddle ofthemotorhead Turn theimpellerguardandpull itawayandoutof themotorhead youwillthenhavefull accesstothe impellerandshaft EF1 EF2 EFX Simplywashthisandcleanthiswit...

Page 10: ...eyouractivatedcarbonatleastevery2 3monthsas afterthis timeitispossiblethatthecarboncanhaveanegativee ectonyour aquariumasthevery wasteitremovescanbereleasedfromthecarbonback into theaquarium When clea...

Page 11: ...besaturatedwithwater Liftthe ltermedia baskets outofthecanisterandplace them inyoursink oralarge bucket 8 Rinse theinside ofthecanisterwith clearaquariumwater NEVER usetap water or soapordetergents wh...

Page 12: ...dcarefullyexamineforanydamageorcracks Takecare whenhandlingthequartzsleeveandUVbulbto avoid any damage to the glass Pleasenote theUVbulbshouldbereplacedevery6months evenif thebulbisstillworking Doingt...

Page 13: ......

Page 14: ...lhosing part7 andpipeworkareconnectedcorrectly airtighta n d unrestricted ChecktheEF lterbody part5 ltermedia hosing part7 andallpipeworkfor a build up of restrictive waste and clean if required No Wa...

Page 15: ...mentshavebrokeninsidethe UV bulb Re insert the UV bulb ensuring that it is seated correctly in its holder and re assembletheEF TesttheUVbulbagainbypressingtheredswitchon topofthe EF lter head IftheUVi...

Page 16: ...sethegraveluntilthewaterrunsclear That should resolve theproblem Dissolvedconstituents ifwashingthegraveldoesn tsolvethe problem the nextmostlikelycauseofcloudywaterinanewly lled tankisahighlevelof di...

Page 17: ...turallyhasahighlevelof phosphate youwill needtouseaphosphateremovertotreatitafter give your sh Nitrates Asthe amountof shwasterisessodothe nitrates Make adequate for youraquariumsizeanddonotoverstock...

Page 18: ...EFwithout thesurface skimmer part15 attached this can bere attached afterpriming EnsuretheEF lterbody part5 isnotoverstockedwithmediaandfoama s this can restrictwater owand a ect the priming function...

Page 19: ......

Page 20: ......

Reviews: