background image

IMPROPER INSTALLATION OF THE GROUNDING PLUG CAN RESULT IN A RISK OF ELECTRIC SHOCK. IF REPAIR OR REPLACEMENT OF THE
CORD IS NECESSARY, DO NOT CONNECT THE GROUNDING WIRE TO EITHER FLAT BLADE TERMINAL. THE WIRE WITH GREEN INSULATION
WITH OR WITHOUT YELLOW STRIPES IS THE GROUNDING WIRE.

THIS PRODUCT IS FOR USE ON A NOMINAL 120-VOLT CIRCUIT AND HAS A THREE-PRONG GROUNDING PLUG THAT LOOKS LIKE THE PLUG
ILLUSTRATED IN FIGURE 1. A TEMPORARY ADAPTER SIMILAR TO THE ADAPTER ILLUSTRATED IN SKETCH B AND C (SEE PAGE 5) MAY BE
USED TO CONNECT THIS PLUG TO A 2-POLE RECEPTACLE AS SHOWN IN ILLUSTRATION B WHEN A PROPERLY GROUNDED OUTLET IS NOT
AVAILABLE. THE TEMPORARY ADAPTER SHALL BE USED ONLY UNTIL A PROPERLY GROUNDED OUTLET (ILLUSTRATION A) IS INSTALLED BY A
QUALIFIED ELECTRICIAN. TAB FOR GROUNDING SCREW, LUG, OR SIMILAR PART EXTENDING FROM THE ADAPTER MUST BE CONNECTED
TO A PERMANENT GROUND SUCH AS A PROPERLY GROUNDED OUTLET BOX COVER. WHENEVER THE ADAPTER IS USED, IT MUST BE HELD
IN PLACE BY A METAL SCREW.

THE USE OF A GFCI OUTLET IS STRONGLY RECOMMENDED. THE THIRD PRONG IS TO BE USED TO GROUND THE TOOL AND PROVIDE
PROTECTION AGAINST ELECTRICAL SHOCK. NEVER REMOVE THE THIRD PRONG.

CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICEMAN IF THE GROUNDING INSTRUCTIONS ARE NOT COMPLETELY UNDERSTOOD, OR IF
IN DOUBT AS TO WHETHER THE PRODUCT IS PROPERLY GROUNDED. DO NOT MODIFY THE PLUG PROVIDED. IF IT WILL NOT FIT THE
OUTLET, HAVE THE PROPER OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN.

Extension Cords
THE USE OF AN EXTENSION CORD WITH THIS PRODUCT IS NOT RECOMMENDED

as this can result in the loss of power to your air

compressor which can prevent the motor from starting or running properly. This can also cause your fuse to blow or circuit breaker to trip.
Running your air compressor on an undersized extension cord will cause permanent damage to internal switches and overheating of the 
electric motor. Use an additional length of air hose rather than an extension cord.

If you must use an extension cord, it should be plugged into a GFCI found in circuit boxes or protected receptacles. Use only UL listed 3-wire
extension cords that have a 3-blade grounding plug and a 3-slot receptacle that will accept the plug on the product. Make sure your extension
cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. Refer to
the guide below for minimum gauge required for extension cords.

Use only extension cords that are intended for outdoor use. These cords are identified by a marking “ACCEPTABLE FOR USE WITH OUTDOOR
APPLIANCES, STORE INDOORS WHEN NOT IN USE.” Examine extension cord before use. DO NOT USE DAMAGED EXTENSION CORDS. Do not
pull on cord to disconnect from receptacle; always disconnect by pulling on plug. Keep cord away from heat and sharp edges. Always shut OFF
the air compressor AUTO/ON pressure switch before unplugging the compressor. Always disconnect the extension cord from the receptacle
before disconnecting the product from the extension cord.

AVOID ELECTRICAL SHOCK HAZARD. NEVER USE THIS COMPRESSOR WITH A DAMAGED OR FRAYED 

ELECTRICAL CORD OR EXTENSION CORD. INSPECT ALL ELECTRICAL CORDS REGULARLY. 

NEVER USE IN OR NEAR WATER OR IN ANY ENVIRONMENT WHERE ELECTRIC SHOCK IS POSSIBLE. 

TO REDUCE THE RISK OF ELECTROCUTION, KEEP ALL CONNECTIONS DRY AND OFF THE GROUND. 

DO NOT TOUCH THE PLUG WITH WET HANDS.

Guard against electrical shock. Avoid body contact with grounded services such as pipes, ovens, stoves, and refrigerator enclosures. If not
properly grounded, this air compressor can incur the potential hazard of light trickle shock, particularly when used in damp locations. If
electrical shock occurs, there is the potential of secondary hazard such as your hands contacting an operating air tool.

COMPRESSOR FEATURES

6

DANGER

EXTENSION CORD LENGTH

WIRE SIZE (AWG)

Up to 25 Feet

16

26 to 50 Feet

12

51 to 100 Feet

10

Summary of Contents for 647376

Page 1: ...Gallon 3 Peak HP 226892 If you encounter any problems or difficulties Do not return your compressor to the store Please contact our toll free customer service department at 1 800 423 3598 1 310 522 90...

Page 2: ...tood prior to usage The air compressor shall be inspected per the operating instructions Users of this air compressor must fully understand these instructions Each person operating this air compressor...

Page 3: ...g the OFF time the motor is stopped and the tools are running off on the pressurized air stored in the tank If your air tools are draining pressure off of the tank too quickly the compressor motor mus...

Page 4: ...ury Indicates a potentially hazardous situation that if not avoided MAY result in minor or moderate injury Indicates important information which if not followed MAY cause damage to equipment UNPACKING...

Page 5: ...ance tools away from the immediate area before turning ON your air compressor Do not overreach Proper footing and balance is a must at all times while using tools Unstable support may lead to personal...

Page 6: ...tempt to alter the factory set operating pressures RISK OF ELECTRICAL SHOCK Disconnect air compressor from power source before servicing USE PROPERLY grounded ELECTRICAL CONNECTIONS DO NOT use groundi...

Page 7: ...ean and well ventilated area The compressor requires an unobstructed airflow and must be located a minimum of 20 inches from any walls or other obstructions that may prevent proper ventilation DO NOT...

Page 8: ...switches and overheating of the electric motor Use an additional length of air hose rather than an extension cord If you must use an extension cord it should be plugged into a GFCI found in circuit bo...

Page 9: ...7 COMPRESSOR FEATURES 3 4 5 6 7 8 10 12 13 9 11 12 1 2...

Page 10: ...gulator knob when it bottoms out as this may damage pressure regulator OUTLET PRESSURE GAUGE The outlet pressure gauge provides a reading of the air pressure at the outlet side of the regulator This p...

Page 11: ...WITHOUT OIL IN THE CRANKCASE ADD OIL AS INDICATED BELOW STEP 1 PUMP LUBRICATION This air compressor features an oil lubricated pump that requires the use of SAE 30 weight non detergent air compressor...

Page 12: ...lease pressure from the system Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise Tilt tank to remove all moisture Once all the moisture has drained out c...

Page 13: ...ement These used parts including air filters and used lubricating oil may contain regulated substances that must be disposed of in accordance with local state and federal laws and regulations 1 Turn c...

Page 14: ...ty relief valve if plunger does not move or is difficult to move CHECKING AIR FILTER ELEMENT 1 The air compressor must be turned OFF 2 Disconnect compressor from the power source 3 Open tank drain to...

Page 15: ...ively noisy operation Loose motor pulley or pump flywheel Tighten pulley and or flywheel where applicable Lack of oil in the pump crankcase Check oil level If low check for possible bearing damage Add...

Page 16: ...kage points Tighen or replace leaking fittings or connections as needed Hose or hose connections are too small or long Replace with larger hose or connectors Air compressor is not large enough for air...

Page 17: ...7376 77 Gasket 1 24 647376 24 Bolt LH 1 78 647376 78 Connecting 1 25 647376 25 Oil Fill Plug 1 79 647376 79 Check Valve 1 26 647376 26 Screw 6 80 647376 80 Grip Handle 1 27 647376 27 Oil Sight 1 81 64...

Page 18: ...16 PARTS DIAGRAM...

Page 19: ...em Warranty coverage is conditioned upon purchaser furnishing Alltrade with adequate written proof that they are the original purchaser and of the original purchase date Parts returned freight prepaid...

Page 20: ...ESENTATION WRITTEN OR ORAL ARISES BY OPERATION OF LAW AND OR EQUITY AND OR BY ANY ACT OR OMISSION OF ALLTRADE AND OR ITS REPRESENTATIVE S OR THE PURCHASER INCLUDING BUT NOT LIMITED TO THE IMPLIED WARR...

Page 21: ...each CA 90810 1462 USA Made in China 2006 REV 1 Alltrade Tools LLC www alltradetools com HOT ROD Magazine is a trademark of PRIMEDIA Specialty Group Inc and is used with permission 2006 PRIMEDIA Speci...

Reviews: