background image

SAFETY WARNINGS

READ ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR.

GENERAL SAFETY WARNINGS:

• Keep work area clean. Messy areas and cluttered workbenches invite personal injury and/or property damage.
• Keep children and visitors away. All children should be kept away from the work area. DO NOT let children handle the compressor or

extension cord. Maintain a safe distance for any person near the work area.

• Operating any tools or equipment under the influence of drugs, alcohol, or medication can cause personal injury to yourself and others.
• Wear proper apparel. Remove your jewelry before using air compressor. Do not wear loose clothing, necklaces, rings, bracelets, or other

jewelry, which may get caught in moving parts. Nonskid footwear and electrically non-conductive gloves are highly suggested while working.
Wear protective hair covering to contain long hair.

• Protect your eyes. The operation of any air compressor can result in foreign objects being thrown into the eyes, which can result in severe

eye damage. Always wear eye protection that meets ANSI Z28.1 specifications during air compressor operation. Eyeglasses are not always
safety glasses.

• Be responsible for your hearing. Wear hearing protection during extended periods of operation.
• Use the right tool. Use tools properly and for their intended task. Do not force a small tool to do the job of a heavy-duty tool. Using the

right tool to do the right job will make doing the job safer.

• Check damaged parts before use of any air tools or attachments. A guard or other part that is damaged should be carefully checked to

ensure that it will operate properly and perform its intended function. Check for misalignment or binding of moving parts, breakage of
parts, mounting, or any other conditions that may affect tool operation. A guard or other part that is damaged should be properly replaced.
See replacement parts list for additional details.

• Avoid unintentional starting. Be sure that your air compressor is in the OFF position before plugging it into a power cord or electrical

receptacle.

• Store all maintenance tools away from the immediate area before turning ON your air compressor.
• Do not overreach. Proper footing and balance is a must at all times while using tools. Unstable support may lead to personal injury. Do not

stand on the tool. Serious injury could result if the tool tips over or you accidentally contact tool.

• Never leave the air compressor running unattended. Always turn the power to the OFF position and do not leave the air compressor until 

it comes to a complete stop.

• When using air accessories, consult the owner’s manual provided by the manufacturer. The use of improper accessories may cause risk of

injury to yourself and others.

• Always make sure the tool is in the OFF position and unplugged from the electrical receptacle when making adjustments, changing parts, or

performing any maintenance.

• Secure work. When possible, the use of clamps or a holding device is much safer than holding the work piece with your hands.
• Keep protective guards in place and in proper working condition.
• Maintain tools and equipment with care. They will function better and more safely when kept clean and in good working condition. Keeping

the air compressor clean, dry, and free of grime will add to its life and performance.

• Childproof the workshop. The use of master switches and padlocks is highly recommended. Remove starter keys where applicable.

• SOME DUST CREATED BY SPRAYING, BLOWING, POWER SANDING, SAWING, GRINDING, DRILLING AND OTHER CONSTRUCTION

ACTIVITIES CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER
REPRODUCTIVE HARM. REDUCE YOUR EXPOSURE TO THESE CHEMICALS BY WEARING APPROVED SAFETY EQUIPMENT SUCH AS DUST
MASKS THAT ARE DESIGNED TO FILTER OUT MICROSCOPIC PARTICLES.

• USE OF THIS PRODUCT WILL EXPOSE YOU TO CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS,

AND REPRODUCTIVE HARM. 

AVOID INHALING VAPORS AND DUST. WASH HANDS AFTER USING.

• THIS PRODUCT CONTAINS CHEMICALS, INCLUDING LEAD, KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS,

AND REPRODUCTIVE HARM. 

WASH HANDS AFTER HANDLING.

• HANDLING THE POWER CORD ON THIS PRODUCT MAY EXPOSE YOU TO LEAD, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO

CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. 

WASH HANDS AFTER HANDLING.

3

Summary of Contents for 835446

Page 1: ...Gallon 2 Peak HP 3043653 If you encounter any problems or difficulties Do not return your compressor to the store Please contact our toll free customer service department at 1 800 423 3598 1 310 522 9...

Page 2: ...tood prior to usage The air compressor shall be inspected per the operating instructions Users of this air compressor must fully understand these instructions Each person operating this air compressor...

Page 3: ...he tank During the OFF time the motor is stopped and the tools are running off on the pressurized air stored in the tank If your air tools are draining pressure off of the tank too quickly the compres...

Page 4: ...ury Indicates a potentially hazardous situation that if not avoided MAY result in minor or moderate injury Indicates important information which if not followed MAY cause damage to equipment UNPACKING...

Page 5: ...ance tools away from the immediate area before turning ON your air compressor Do not overreach Proper footing and balance is a must at all times while using tools Unstable support may lead to personal...

Page 6: ...tempt to alter the factory set operating pressures RISK OF ELECTRICAL SHOCK Disconnect air compressor from power source before servicing USE PROPERLY grounded ELECTRICAL CONNECTIONS DO NOT use groundi...

Page 7: ...ean and well ventilated area The compressor requires an unobstructed airflow and must be located a minimum of 20 inches from any walls or other obstructions that may prevent proper ventilation DO NOT...

Page 8: ...switches and overheating of the electric motor Use an additional length of air hose rather than an extension cord If you must use an extension cord it should be plugged into a GFCI found in circuit bo...

Page 9: ...7 COMPRESSOR FEATURES 1 2 4 7 3 5 10 8 6 11 12 9...

Page 10: ...e air outlet Valve is attached to the pressure regulator and can be open or closed to allow for shut off air flow It is recommended to attach a quick connect air coupler not included for quick connect...

Page 11: ...OR WITHOUT LUBRICANT OR WITH LOW LUBRICATION LEVEL THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGE CAUSED TO THE COMPRESSOR DUE TO OPERATION WITHOUT PROPER LUBRICATION STEP 2 INSPECTION CHECK Assembly...

Page 12: ...urely NOTE Air tank will not pressurize while drain valve is open 13 Disconnect the power cord from the power outlet NOTE Make sure the power switch is in the OFF position when connecting or disconnec...

Page 13: ...the system Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise Tilt tank to remove all moisture Once all the moisture has drained out close the fitting se...

Page 14: ...r pressure before attempting any maintenance or repair 4 Allow compressor to fully cool before attempting any maintenance or repair 5 Remove the face of the filter body to access the filter element by...

Page 15: ...ely noisy operation Loose motor pulley or pump flywheel Tighten pulley and or flywheel where applicable Lack of oil in the pump crankcase Check oil level If low check for possible bearing damage Add c...

Page 16: ...kage points Tighen or replace leaking fittings or connections as needed Hose or hose connections are too small or long Replace with larger hose or connectors Air compressor is not large enough for air...

Page 17: ...1 23 835446T 23 Crankcase Gasket 1 24 835446T 24 Front Bracket 1 25 835446T 25 Sealing Ring 1 26 835446T 26 Bearing 6003 1 27 835446T 27 Stator 1 28 835446T 28 Rotor 1 29 835446T 29 Bearing 6202 1 30...

Page 18: ...16 PARTS DIAGRAM...

Page 19: ...purchaser Alltrade shall not be responsible or liable for any expense including freight charges or repairs made outside Alltrade s facility unless expressly agreed to by Alltrade in writing Under no c...

Page 20: ...AND OR THE EXISTENCE DESIGN MANUFACTURE PURCHASE USE AND OR OPERATION OF ANY ITEM S SOLD HEREUNDER EVEN IF ALLTRADE AND OR ITS REPRESENTATIVE S HAS BEEN ADVISED OF THE POSSIBILITY OF ANY SUCH DAMAGES...

Page 21: ...WEAR SAFETY GLASSES WARNING ADVERTENCIA USE GAFAS DE SEGURIDAD ALLTRADE TOOLS LLC 1431 VIA PLATA LONG BEACH CA 90810 1462 www alltradetools com COPYRIGHT 2006 ALLTRADE TOOLS LLC REV 1...

Reviews: