background image

DO NOT OPERATE THE COMPRESSOR WITHOUT LUBRICANT, OR WITH LOW LUBRICATION LEVEL. ALLTRADE IS NOT RESPONSIBLE

FOR DAMAGE CAUSED TO THE COMPRESSOR DUE TO OPERATION WITHOUT PROPER LUBRICATION.

STEP 5 - INSPECTION CHECK

Assembly Check:

In order to complete the assembly of your new air compressor, a careful inspection should be made to ensure that all of the parts are
properly aligned and securely fastened.
1.

Inspect wheels to ensure that they are properly mounted and secured to ground irons.

2.

Inspect rubber feet to ensure that they are properly mounted and secured to ground iron.

3.

Inspect handle crosspiece to ensure that it is fully secured.

4.

Inspect air filter to ensure that it is installed and secure.

5.

Check oil fill level in crankcase.

OPERATION

INITIAL SETUP / BREAK-IN PROCEDURE

Do not attach air hose, air tools or other air accessories to the air outlet until break-in procedure has been successfully completed.

1.

Read and understand the entire instruction manual, including all safety warnings before setting up air compressor.

2.

Place air compressor on a flat, level surface.

3.

Check oil fill level in crankcase and add oil as needed.

4.

Turn the pressure regulator knob fully clockwise to open airflow from air outlet port. 

NOTICE: Be careful not to over tighten pres-

sure regulator knob when it “bottoms out” as this may damage pressure regulator.

5.

Turn the power switch to the OFF position.

6.

Plug power cord directly into a properly grounded power source of the correct voltage (see Grounding Instructions on page 7 of
this instruction manual).

7.

Open the tank drain valve to allow air to escape preventing air pressure buildup in the air tank.

8.

Turn the compressor on by moving the switch to the AUTO/ON position and run the air compressor for a period of 20 minutes to
break-in the air pump.

9.

With the compressor still running, at the end of the 20-minute break-in period, close the tank drain valve. The air compressor will
build air pressure to the maximum preset pressure (“cut-out” pressure) and automatically shut off.

10. Slowly turn the tank drain valve to open airflow from drain and bleed off air from the air tank. The air compressor will automatically

restart once the pressure in the air tank drops below the minimum preset pressure (“cut-in” pressure).

11. Turn the compressor off by moving the switch to the OFF position.
12. Release pressure from the system. Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise.

Tilt tank to remove all moisture. Once all the moisture has drained out, close the fitting securely. NOTE: Air tank will not pressurize
while drain valve is open.

13. Disconnect the power cord from the power outlet. NOTE: Make sure the power switch is in the OFF position when connecting or

disconnecting power cord from electrical outlet.

14. Attach the supplied recoil air hose to the air outlet port located on the air compressor regulator valve. Use PTFE thread-sealing tape

on the threads to make sure you have an airtight connection. Do not over tighten fittings.

15. Attach quick connect coupler to the remaining end of the recoil air hose. Again, use PTFE thread-sealing tape on the threads to

make sure you have an airtight connection.

16. Attach any remaining air accessories required by your application.
17. Your new air compressor is now ready to use. 

STARTUP:

1.

Before each startup, make sure the power switch is in the OFF position.

2.

Place air compressor on a flat, level surface.

3.

Check oil fill level in crankcase and add oil as needed.

4.

Release pressure from the system. Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise.
Once all the moisture has drained out, close the fitting securely. NOTE: Air tank will not pressurize while drain valve is open.

5.

Turn the pressure regulator knob fully counterclockwise to close airflow from air outlet port.

6.

Attach air hose and accessories

10

CAUTION

WARNING

Summary of Contents for Air-Plus 540010

Page 1: ...1GALLON GALONES OIL LUBRICATED AIR COMPRESSOR COMPRESSEUR D AIR LUBRIFI PAR HUILE COMPRESOR DE AIRE CON LUBRICACI N DE ACEITE INSTRUCTION MANUAL Do Not Return Your Compressor to the Store Call 1 800 4...

Page 2: ...f any substance that might impair their vision dexterity or judgment Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury...

Page 3: ...ngs are secure before putting this air compressor into service If you have any questions or require assistance with damaged or missing parts please contact our factory customer service department at 1...

Page 4: ...compressor running unattended Always turn the power to the off position and do not leave the air compressor until it come to a complete stop When using air accessories consult the owner s manual provi...

Page 5: ...n place Never attempt to repair or make modifications to the tank or its attachments Welding drilling or any other modifications may weaken the tank which may result in damage from rupture or explosio...

Page 6: ...xcess pressure can cause them to explode resulting in serious injury Follow the manufacturers recommended pressure settings for all air tools and air accessories SPECIFICATIONS 3 5 Peak HP 11 Gallon A...

Page 7: ...stead of an extension cord However if the use of an extension cord is unavoidable use only UL listed three wire extension cords that have three pronged ground ing type plugs and three prong receptacle...

Page 8: ...r pressure reaches a predetermined level The safety relieve valve is preset by the manu facturer DO NOT attempt to modify or remove the safety relief valve 9 AIR TANK DRAIN VALVE Moisture is produced...

Page 9: ...Slide foam grip so that it is centered over end of horizontal handle cross piece 2 Position the horizontal handle crosspiece over the tops of the handle receivers lining up the openings in the crossp...

Page 10: ...minute break in period close the tank drain valve The air compressor will build air pressure to the maximum preset pressure cut out pressure and automatically shut off 10 Slowly turn the tank drain v...

Page 11: ...4 Remove the air hose and any air accessories 5 Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise Tilt tank to remove all moisture Once all the moisture...

Page 12: ...move oil drain plug 4 Allow oil to drain completely Tilt air compressor towards the oil drain to assist draining 5 Clean and replace oil drain plug 6 Refill crankcase with SAE 30 weight non detergent...

Page 13: ...ockwise until the filter is hand tight DO NOT OVERTIGHTEN MOISTURE IN COMPRESSED AIR Moisture is a normal by product of compressing air As the moisture builds during compressor use it can be carried t...

Page 14: ...rd Replace fuse or reset circuit breaker Check for proper fuse amperage Check for low voltage conditions Disconnect any other electrical appliances from cir cuit or operate air compressor on its own b...

Page 15: ...on If the motor does not shut off unplug the air compressor If the electrical contacts are welded together replace the pressure switch Limit the air pressure to the capacity of the air com pressor Eit...

Page 16: ...oap solution to all fit tings and connections Bubbles will appear at leak age points Tighen or replace leaking fittings or con nections as needed Replace with larger hose or connectors Check the acces...