background image

14

TROUBLESHOOTING GUIDE

Problem Encountered

Possible Cause

Possible Solution

The compressor does not
start or restart:

The compressor motor
stalls:

Excessively noisy opera-
tion:

Power cord not plugged in.

Motor/Pressure switch in "OFF" position

Motor thermal overload switch has tripped.

Fuse blown or circuit breaker has tripped.

Wrong gauge wire or length of extension
cord.

Air tank pressure exceeds motor/pressure
switch "cut-in" pressure.

Pressure release valve on motor/pressure
switch has not unloaded pump head pres-
sure.

Defective motor, motor capacitor,
motor/pressure switch.

Overloaded motor.

Improper lubrication.

Low oil level.

Defective check valve.

Loose motor pulley or pump flywheel.

Lack of oil in the pump crankcase.

Carbon deposits on pistons or valves.

Bearing, piston or connecting rod failure.

Worn connecting rod.

Worn piston wrist pin bushing.

Worn bearings.

Noisy check valve.

Plug cord into grounded outlet.

Move switch to "AUTO" position.

Turn air compressor off, wait until the motor is cool,
then press motor thermal overload (red) button firm-
ly until click is heard.

Replace fuse or reset circuit breaker.
Check for proper fuse amperage.
Check for low voltage conditions.
Disconnect any other electrical appliances from cir-
cuit or operate air compressor on its own branch cir-
cuit.

Check chart in instruction manual for proper gauge
wire and cord length.

Motor will start automatically when air tank pressure
drops below "cut-in" pressure of motor/pressure
switch.

Bleed the line by moving the switch to the "OFF"
position.

Contact Factory Customer Service at 
1-800-423-3598.

Have a certified electrician check the motor and
wiring, then proceed with his or her recommenda-
tions.

See LUBRICATION section in instruction manual.

Check oil level and fill if necessary.

Replace check valve.

Tighten pulley and/or flywheel (where applicable).

Check oil level. If low, check for possible bearing
damage. Add correct amount of oil.

Remove cylinder head and inspect. Clean or replace
parts as needed.

STOP THE COMPRESSOR! Contact Factory
Customer Service at 1-800-423-3598.

Replace with new connecting rod.

Remove piston/connecting rod assembly from the
compressor and inspect for excess wear. Replace
worn parts as needed.

Replace worn bearings as needed. Note: Dirty oil can
cause accelerated wear. Change oil frequently using
recommended oil.

Replace check valve.

Summary of Contents for Air-Plus 540010

Page 1: ...1GALLON GALONES OIL LUBRICATED AIR COMPRESSOR COMPRESSEUR D AIR LUBRIFI PAR HUILE COMPRESOR DE AIRE CON LUBRICACI N DE ACEITE INSTRUCTION MANUAL Do Not Return Your Compressor to the Store Call 1 800 4...

Page 2: ...f any substance that might impair their vision dexterity or judgment Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury...

Page 3: ...ngs are secure before putting this air compressor into service If you have any questions or require assistance with damaged or missing parts please contact our factory customer service department at 1...

Page 4: ...compressor running unattended Always turn the power to the off position and do not leave the air compressor until it come to a complete stop When using air accessories consult the owner s manual provi...

Page 5: ...n place Never attempt to repair or make modifications to the tank or its attachments Welding drilling or any other modifications may weaken the tank which may result in damage from rupture or explosio...

Page 6: ...xcess pressure can cause them to explode resulting in serious injury Follow the manufacturers recommended pressure settings for all air tools and air accessories SPECIFICATIONS 3 5 Peak HP 11 Gallon A...

Page 7: ...stead of an extension cord However if the use of an extension cord is unavoidable use only UL listed three wire extension cords that have three pronged ground ing type plugs and three prong receptacle...

Page 8: ...r pressure reaches a predetermined level The safety relieve valve is preset by the manu facturer DO NOT attempt to modify or remove the safety relief valve 9 AIR TANK DRAIN VALVE Moisture is produced...

Page 9: ...Slide foam grip so that it is centered over end of horizontal handle cross piece 2 Position the horizontal handle crosspiece over the tops of the handle receivers lining up the openings in the crossp...

Page 10: ...minute break in period close the tank drain valve The air compressor will build air pressure to the maximum preset pressure cut out pressure and automatically shut off 10 Slowly turn the tank drain v...

Page 11: ...4 Remove the air hose and any air accessories 5 Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise Tilt tank to remove all moisture Once all the moisture...

Page 12: ...move oil drain plug 4 Allow oil to drain completely Tilt air compressor towards the oil drain to assist draining 5 Clean and replace oil drain plug 6 Refill crankcase with SAE 30 weight non detergent...

Page 13: ...ockwise until the filter is hand tight DO NOT OVERTIGHTEN MOISTURE IN COMPRESSED AIR Moisture is a normal by product of compressing air As the moisture builds during compressor use it can be carried t...

Page 14: ...rd Replace fuse or reset circuit breaker Check for proper fuse amperage Check for low voltage conditions Disconnect any other electrical appliances from cir cuit or operate air compressor on its own b...

Page 15: ...on If the motor does not shut off unplug the air compressor If the electrical contacts are welded together replace the pressure switch Limit the air pressure to the capacity of the air com pressor Eit...

Page 16: ...oap solution to all fit tings and connections Bubbles will appear at leak age points Tighen or replace leaking fittings or con nections as needed Replace with larger hose or connectors Check the acces...

Reviews: