GROUNDING INSTRUCTIONS

This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an
escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug.
The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Improper installation of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord is necessary, do
not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or with-
out yellow stripes is the grounding wire.

This product is for use on a nominal 120-volt circuit and has a three-prong grounding plug that
looks like the plug illustrated in Figure 1. Make sure that the product is connected to an outlet
having the same configuration as the plug. No adapter could be used with this product.

The use of a GFCI outlet is strongly recommended. The third prong is to be used to ground the
tool and provide protection against electrical shock. Never remove the third prong.

Check with a qualified electrician or serviceman if the grounding instructions are not completely
understood, or if in doubt as to whether the product is properly grounded. Do not modify the plug
provided; if it will not fit the outlet, have the proper outlet installed by a qualified electrician.

Extension Cords

- Alltrade does not recommend the use on an extension cord with this product as this may result in the loss of power

and overheating of the motor. An additional air hose should be used instead of an extension cord. 

However, if the use of an extension cord is unavoidable, use only UL listed three wire extension cords that have three-pronged ground-
ing type plugs and three prong receptacles that accept the tool's plug. Improper use of extension cords may cause inefficient operation
of your tool, which can result in overheating. Be sure your extension cord is rated to allow sufficient flow to motor. Refer to the guide
below for minimum gauge required for extension cords.

Extension Cord Length

Wire Size (A.W.C.)

Up to 25 Feet

14

26 to 50 Feet

12

51 to 100 Feet

10

Use of an extension cord rated to carry the current the tool will draw is very important, especially when the power source is at great
distance. An extension cord of insufficient rating will cause a drop in line voltage, resulting in power loss and causing the motor to
overheat.

Guard against electrical shock. Avoid body contact with grounded services such as pipes, radiators, ovens, stoves, and refrigerator
enclosures. If not properly grounded, this power tool can incur the potential hazard of light trickle shock, particularly when used in
damp locations. If an electrical shock occurs, there is the potential of a secondary hazard such as your hands contacting an operating
air tool.

COMPRESSOR FEATURES

1.

Oil Lubrication: 

Oil lubricated direct drive pump with cast-iron cylinder for durability.

2.

OIL FILL SIGHT GLASS: 

Located on the face of the crankcase, the oil fill sight glass provides a convenient way to check the oil fill

level within the pump. The oil level must be checked prior to each use to ensure proper fill level.

DO NOT OPERATE THE COMPRESSOR WITHOUT LUBRICANT, OR WITH LOW LUBRICATION LEVEL. ALLTRADE IS NOT RESPONSIBLE

FOR DAMAGE CAUSED TO THE COMPRESSOR DUE TO OPERATION WITHOUT PROPER LUBRICATION.

7

DANGER

CAUTION

WARNING

Figure 1

Grounded Outlet Box

Grounded Outlet

Plug

Grounding Plug

115 Volts

15 AMP

Summary of Contents for Air-Plus 540010

Page 1: ...1GALLON GALONES OIL LUBRICATED AIR COMPRESSOR COMPRESSEUR D AIR LUBRIFI PAR HUILE COMPRESOR DE AIRE CON LUBRICACI N DE ACEITE INSTRUCTION MANUAL Do Not Return Your Compressor to the Store Call 1 800 4...

Page 2: ...f any substance that might impair their vision dexterity or judgment Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury...

Page 3: ...ngs are secure before putting this air compressor into service If you have any questions or require assistance with damaged or missing parts please contact our factory customer service department at 1...

Page 4: ...compressor running unattended Always turn the power to the off position and do not leave the air compressor until it come to a complete stop When using air accessories consult the owner s manual provi...

Page 5: ...n place Never attempt to repair or make modifications to the tank or its attachments Welding drilling or any other modifications may weaken the tank which may result in damage from rupture or explosio...

Page 6: ...xcess pressure can cause them to explode resulting in serious injury Follow the manufacturers recommended pressure settings for all air tools and air accessories SPECIFICATIONS 3 5 Peak HP 11 Gallon A...

Page 7: ...stead of an extension cord However if the use of an extension cord is unavoidable use only UL listed three wire extension cords that have three pronged ground ing type plugs and three prong receptacle...

Page 8: ...r pressure reaches a predetermined level The safety relieve valve is preset by the manu facturer DO NOT attempt to modify or remove the safety relief valve 9 AIR TANK DRAIN VALVE Moisture is produced...

Page 9: ...Slide foam grip so that it is centered over end of horizontal handle cross piece 2 Position the horizontal handle crosspiece over the tops of the handle receivers lining up the openings in the crossp...

Page 10: ...minute break in period close the tank drain valve The air compressor will build air pressure to the maximum preset pressure cut out pressure and automatically shut off 10 Slowly turn the tank drain v...

Page 11: ...4 Remove the air hose and any air accessories 5 Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise Tilt tank to remove all moisture Once all the moisture...

Page 12: ...move oil drain plug 4 Allow oil to drain completely Tilt air compressor towards the oil drain to assist draining 5 Clean and replace oil drain plug 6 Refill crankcase with SAE 30 weight non detergent...

Page 13: ...ockwise until the filter is hand tight DO NOT OVERTIGHTEN MOISTURE IN COMPRESSED AIR Moisture is a normal by product of compressing air As the moisture builds during compressor use it can be carried t...

Page 14: ...rd Replace fuse or reset circuit breaker Check for proper fuse amperage Check for low voltage conditions Disconnect any other electrical appliances from cir cuit or operate air compressor on its own b...

Page 15: ...on If the motor does not shut off unplug the air compressor If the electrical contacts are welded together replace the pressure switch Limit the air pressure to the capacity of the air com pressor Eit...

Page 16: ...oap solution to all fit tings and connections Bubbles will appear at leak age points Tighen or replace leaking fittings or con nections as needed Replace with larger hose or connectors Check the acces...