background image

3.

AUTOMATIC ON/OFF PRESSURE SWITCH: 

This compressor is equipped with an automatic on/off pressure switch. The compressor

will only run when the switch is in the “I” (ON) position. Once the tank has reached the desired preset pressure (“cut-out” pres-
sure), the pump motor will automatically shut off. While the switch is in the “I” (ON) position, the pump motor will automatically
turn back on once the pressure in the tank drops below the minimum preset pressure (“cut-in” pressure).

DO NOT LEAVE THE COMPRESSOR UNATTENDED WHILE THE POWER SWITCH IS IN THE “I” (ON) POSITION.

4.

AIR TANK PRESSURE GAUGE:

The tank pressure gauge provides a reading of the air pressure inside of the compressor tank.

5.

PRESSURE REGULATOR:

The regulator allows you to select the amount of air pressure that is output through the air hose into

tools and accessories. Turn the pressure regulator knob clockwise to increase discharge pressure, and counter clockwise to
decrease discharge pressure. Please refer to the air delivery requirements of your tools for the proper pressure settings. 

NOTICE:

Be careful not to over tighten pressure regulator knob when it “bottoms out” as this may damage pressure regulator.

6.

OUTLET PRESSURE GAUGE: 

The outlet pressure gauge provides a reading of the air pressure at the outlet side of the regulator.

This pressure is controlled by the pressure regulator and is always less than or equal to the air tank pressure.

7.

AIR OUTLET PORT: 

The air outlet port is located on the pressure regulator body. This port is threaded to accommodate standard

1/4" NPT (M) air fittings found on air hoses and quick connectors. Use PTFE thread-sealing tape on the threads to make sure you
have an airtight connection.

8.

SAFETY RELIEF VALVE: 

This compressor is equipped with a safety relief valve that is designed to prevent system failures by reliev-

ing pressure from the system when the air pressure reaches a predetermined level. The safety relieve valve is preset by the manu-
facturer - DO NOT attempt to modify or remove the safety relief valve.

9.

AIR TANK DRAIN VALVE: 

Moisture is produced whenever air is compressed. It is critical to drain water from the air tank on this

compressor frequently. If unit is used only occasionally, tank should be drained after each use and prior to the next use. To drain
the tank, slowly open the tank drain fitting by turning clockwise. Once all moisture has drained out, close the fitting securely. NOTE:
Air tank will not pressurize while drain valve is open.

10. AIR INTAKE FILTER: 

This compressor is equipped with an externally accessible air intake filter that is designed to clean air coming

into the pump. The filter element is easily removed for periodic cleaning with warm soapy water. Rinse the filter and air dry before
reinstalling. Replace filter element when necessary. 

NOTICE: Remove air inlet dust plug and install air filter as indicated in

assembly instructions before using air compressor.

11. THERMAL SHUTDOWN SWITCH:

The electric motor is equipped with an automatic thermal overload protector. If the unit is over-

heating, the motor will automatically shut down. Turn the unit off and allow the unit to cool for approximately 20 minutes before
turning the unit back to the “I” (ON) position. NOTICE: This air compressor is designed for household use only and is not intended
to operate heavy-duty air tools. If your application's demands exceed the capacity of this air compressor, a larger air compressor
that is matched to your application is recommended. If the unit shuts down again, please call factory customer service at 1-800-
423-3598 for assistance.

12. HANDLE: 

Convenient handle for easy transport.

13. WHEELS: 

Large diameter wheels for easy mobility.

ASSEMBLY INSTRUCTIONS

STEP 1 - INSTALLING WHEELS AND RUBBER FEET

THE WHEELS AND HANDLE DO NOT PROVIDE ADEQUATE CLEARANCE, STABILITY OR SUPPORT FOR PULLING THE UNIT UP AND

DOWN STAIRS OR STEPS. THE UNIT MUST BE LIFTED, OR PUSHED UP A RAMP.

8

WARNING

WARNING

Summary of Contents for Air-Plus 540025

Page 1: ...GALLON GALONES OIL LUBRICATED AIR COMPRESSOR COMPRESSEUR D AIR LUBRIFI PAR HUILE COMPRESOR DE AIRE CON LUBRICACI N DE ACEITE INSTRUCTION MANUAL Do Not Return Your Compressor to the Store Call 1 800 4...

Page 2: ...truction manual prior to operation of this unit The owner operator shall retain product instructions for future reference The owner and or operator is responsible for maintenance maintaining all decal...

Page 3: ...ngs are secure before putting this air compressor into service If you have any questions or require assistance with damaged or missing parts please contact our factory customer service department at 1...

Page 4: ...compressor running unattended Always turn the power to the off position and do not leave the air compressor until it come to a complete stop When using air accessories consult the owner s manual provi...

Page 5: ...n place Never attempt to repair or make modifications to the tank or its attachments Welding drilling or any other modifications may weaken the tank which may result in damage from rupture or explosio...

Page 6: ...xcess pressure can cause them to explode resulting in serious injury Follow the manufacturers recommended pressure settings for all air tools and air accessories SPECIFICATIONS 3 5 Peak HP 10 Gallon A...

Page 7: ...stead of an extension cord However if the use of an extension cord is unavoidable use only UL listed three wire extension cords that have three pronged ground ing type plugs and three prong receptacle...

Page 8: ...r pressure reaches a predetermined level The safety relieve valve is preset by the manu facturer DO NOT attempt to modify or remove the safety relief valve 9 AIR TANK DRAIN VALVE Moisture is produced...

Page 9: ...Slide foam grip so that it is centered over end of horizontal handle cross piece 2 Position the horizontal handle crosspiece over the tops of the handle receivers lining up the openings in the crossp...

Page 10: ...minute break in period close the tank drain valve The air compressor will build air pressure to the maximum preset pressure cut out pressure and automatically shut off 10 Slowly turn the tank drain v...

Page 11: ...4 Remove the air hose and any air accessories 5 Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise Tilt tank to remove all moisture Once all the moisture...

Page 12: ...move oil drain plug 6 Allow oil to drain completely Tilt air compressor towards the oil drain to assist draining 7 Clean and replace oil drain plug 8 Refill crankcase with SAE 30 weight non detergent...

Page 13: ...ockwise until the filter is hand tight DO NOT OVERTIGHTEN MOISTURE IN COMPRESSED AIR Moisture is a normal by product of compressing air As the moisture builds during compressor use it can be carried t...

Page 14: ...rd Replace fuse or reset circuit breaker Check for proper fuse amperage Check for low voltage conditions Disconnect any other electrical appliances from cir cuit or operate air compressor on its own b...

Page 15: ...on If the motor does not shut off unplug the air compressor If the electrical contacts are welded together replace the pressure switch Limit the air pressure to the capacity of the air com pressor Eit...

Page 16: ...oap solution to all fit tings and connections Bubbles will appear at leak age points Tighen or replace leaking fittings or con nections as needed Replace with larger hose or connectors Check the acces...

Page 17: ...17...

Page 18: ...k Shaft Vilebrequin C rter 1 20 53181215 Oil Drain Plug Bouchon de vidange Tap n de drenaje del aceite 1 21 533322 Oil Fill Breather Plug Reniflard du r servoir d huile Tap n respiradero llenado de ac...

Page 19: ...48c 50041038 Exhaust Pipe Fitting Raccord de tuyau d chappement Uni n de la tuber a de escape 2 49 200619620 Tubular Handle w Grip Guidon tubulaire avec prise Mango tubular c agarradera 1 50 40862S23...

Reviews: