DIP (SW1) FUNCTIONS DEEPENING 

 

 

 

- DIP 3 

 

ON

 :

   

“PRESSED BUTTON” FUNCTION ACTIVATED 

 

OPENING ORDER  

= OPENING WITH PRESSED BUTTON 

 

CLOSING ORDER  

= CLOSING WITH PRESSED BUTTON (with close pressed an order of “open”  

 

 

 

 

   blocks the closing movement) 

 

THE PEDESTRIAN ORDER IS NOT CONNECTED 

 

DYNAMIC ORDER = OPENING WITH SELF-HOLDING AND CLOSING WITH PRESSED BUTTON 

 

At end opening, an impulse to the dynamic order closes with 

pressed button

 (closing activated, the order release 

for 3 sec. (before arrive at FCC) stops the function = an other impulse connects the opening. 
 
OPEN END-RUN   

=  

STOP THE OPENING 

 

CLOSE END-RUN  

=  

STOP THE CLOSING 

 

BLOCK  

 

 

=  

BLOCK THE MOVEMENT 

 

With DIP8 on ON; “A” HIGH PHOTOCELL 

= PHOTOCELL BLOCKS IN OPENING 

With DIP7 on ON; “B” LOW PHOTOCELL  

= PHOTOCELL BLOCKS IN CLOSING 

With DIP6 on ON; DW24B (edges)   

 

= DW24B BLOCKS IN CLOSING 

With DIP8 on OFF; “A” HIGH PHOTOCELL  

= PHOTOCELL NOT CONNECTED (OR DISACTIVATED) 

With DIP7 on OFF; “B” LOW PHOTOCELL 

= PHOTOCELL NOT CONNECTED 

With DIP6 on OFF; DW24B (edges)   

 

= DW24B NOT CONNECTED 

 

- DIP3 

 

 

OFF

 : 

 PRESSED BUTTON DISACTIVATED 

 

AUTOMATIC OR SEMIAUTOMATIC CYCLE 

 

 

 

 

- DIP1 

 

 

ON

 :  “

LOW” PHOTOCELL STOP TEMPORARILY THE MOUVEMENT 

 

 

 

(stop the movement until the “low” photocell is obscurated, keep the counter of the 

 

 

 

  “Work Time”). 

 
 

 

 

ON : “HIGH” PHOTOCELL BLOCK THE MOUVEMENT (CENTRALE BLOCKED) 

 
 
 
 

Summary of Contents for Micro6R

Page 1: ...AT THE FOLLOWING PRODUCT Product Name Central for Rapid Rolling Door Model Micro6R CONFORMS TO THE FOLLOWING EMC SPECIFICATIONS BASED ON SAMPLE TESTING EN 55011 EN 60335 1 EN 55014 1 EN 60204 1 EN 550...

Page 2: ...K M7 21 22 Input Arial RX Radio 22 Hold 23 24 Exit from RX Radio Channel 2 6 POLE TERM BLOCK M8 25 26 Input N C Contact MUSHROOM 27 28 N O button enter of OPEN 28 29 N O button enter of CLOSE 28 30 N...

Page 3: ...THE CYCLE il pulsante di blocco 5 e 6 di M1 lo spegne OFF THE BLINKER FIRST BLINK 4 SEC BEFORE CLOSING the button of block 5 and 6 of M1 switches it off DIP 6 ON AUTO TEST FUNCTION DW24B ACTIVATED OF...

Page 4: ...e opening OPEN END RUN STOP THE OPENING CLOSE END RUN STOP THE CLOSING BLOCK BLOCK THE MOVEMENT With DIP8 on ON A HIGH PHOTOCELL PHOTOCELL BLOCKS IN OPENING With DIP7 on ON B LOW PHOTOCELL PHOTOCELL B...

Page 5: ...versal time 0 5 sec Dip 4 OFF Dip 3 OFF reversal time 1 sec set of factor Dip 4 ON Dip 3 ON reversal time 2 sec Dip 4 OFF Dip 3 ON reversal time 4 sec Dip 4 ON SHUNTS SET W3 W4 W5 W6 W7 For predisposi...

Page 6: ...working time combination P1 The control works with normally closed End run N C With the gate opened the pause timer It can be bypassed pressing the button of close after the deter minated time P2 will...

Page 7: ...hen the motor opens The motor does not open the door com pletely Control close at once Control reverse the movement bru squely Photocell stops on Open Control does not open Control does not open Times...

Page 8: ...l have a load of 9 Amp And they must be relating to their load periodically checked It is advisable to overhaul the relay contacts every 4 years but always according to the following condi tions Micro...

Reviews: