Installation Advices 

 

1) 

The control should be installed as near the gate as possible. 

2) 

If this is not possible, you should: 

 

Use cables with proper sizes. 

 

Never use a multiwire cable to connect either the motor or all the services (open, close, block, 

 

photocell, end-run), but ALWAYS SEPARATE THE POWER from the Low Tension 

 

(controls and securities) using more cables. 

 

In case of threephase 400V supply it is necessary to place the control near the gate in order to have   

 

the shortest way of the power wires , always separating the low from the very low tension. 

 

If it is not possible, so it is necessary to use screened cables, remembering to earth the cable screen 

 

at the two ends. 

3) 

After every installation check, with a tester Vac., that there isn’t any induction tension on the en-
ters, measuring between the earth and one end of the “Open button” terminal block. If there is an 
“Alternating tension” below 20—30 V (induced tension for cable passage with supply) the system 
is ready to be tested, otherwise it is necessary to overhaul the cable arrangement as described abo-
ve. 

 

Max Loads and Maintenance 

 

The relays set on the control have a load of 9 Amp. And they must be, relating to their load, periodically 
checked. 
It is advisable to overhaul the relay contacts every 4 years, but always according to the following condi-
tions: 
 
Micro 6R control 400V threephase supply 
Max. load permitted : 2,2kW 
Threephase motor cosØ = 0,7 
N° of possible movement: 500.000 
 
Micro 6R control 230V threephase or monophase supply 
Max. load permitted : 1,5kW 
Threephase motor cosØ = 0,7 
N° of possible movement: 500.000 
 
WARNING: Reducing the motor cosØ the n° of possible openings decreases (ex. with cosØ = 0,3 the 
number of movement is halved). 
 

Check always the values of the installed motors 

 

WARNING

 : The above  specifications are adressed to technicians and/or qualified staff.  

All checks and works should be made OUTSIDE the electric and electronic details of the controls. 
Never forget that installations should be made according to law requirements and “Rules of good 
installation”. 

 

It is advisable to protect the control, at least on the upper side, if it could be subject to inclement 
weather. 

 

The ALLTRONIC snc states that the control has been registred.  
Therefore the central will be protected in all its parts by the law. 
It is forbidden to riproduce any part of this manual without written authorisation of the Alltronic 

 

ALLTRONIC S.N.C.—Via Torino, 84—12041 Bene Vagienna (Cuneo) - Italy 

Summary of Contents for Micro6R

Page 1: ...AT THE FOLLOWING PRODUCT Product Name Central for Rapid Rolling Door Model Micro6R CONFORMS TO THE FOLLOWING EMC SPECIFICATIONS BASED ON SAMPLE TESTING EN 55011 EN 60335 1 EN 55014 1 EN 60204 1 EN 550...

Page 2: ...K M7 21 22 Input Arial RX Radio 22 Hold 23 24 Exit from RX Radio Channel 2 6 POLE TERM BLOCK M8 25 26 Input N C Contact MUSHROOM 27 28 N O button enter of OPEN 28 29 N O button enter of CLOSE 28 30 N...

Page 3: ...THE CYCLE il pulsante di blocco 5 e 6 di M1 lo spegne OFF THE BLINKER FIRST BLINK 4 SEC BEFORE CLOSING the button of block 5 and 6 of M1 switches it off DIP 6 ON AUTO TEST FUNCTION DW24B ACTIVATED OF...

Page 4: ...e opening OPEN END RUN STOP THE OPENING CLOSE END RUN STOP THE CLOSING BLOCK BLOCK THE MOVEMENT With DIP8 on ON A HIGH PHOTOCELL PHOTOCELL BLOCKS IN OPENING With DIP7 on ON B LOW PHOTOCELL PHOTOCELL B...

Page 5: ...versal time 0 5 sec Dip 4 OFF Dip 3 OFF reversal time 1 sec set of factor Dip 4 ON Dip 3 ON reversal time 2 sec Dip 4 OFF Dip 3 ON reversal time 4 sec Dip 4 ON SHUNTS SET W3 W4 W5 W6 W7 For predisposi...

Page 6: ...working time combination P1 The control works with normally closed End run N C With the gate opened the pause timer It can be bypassed pressing the button of close after the deter minated time P2 will...

Page 7: ...hen the motor opens The motor does not open the door com pletely Control close at once Control reverse the movement bru squely Photocell stops on Open Control does not open Control does not open Times...

Page 8: ...l have a load of 9 Amp And they must be relating to their load periodically checked It is advisable to overhaul the relay contacts every 4 years but always according to the following condi tions Micro...

Reviews: