Allworx
®
Connect™ Server Family Installation Guide
Page 12
866.ALLWORX * +1 585 421 3850
www.allworx.com
Version: F Revised: June 21, 2018
2.
Align a rack ear on the side of the Connect server so that:
•
the four holes of the rack ear align with the four holes on the side of the Connect server.
•
the perpendicular side of the rack ear aligns with the bottom of the Connect server.
3.
Align the four holes on the rack ear with the four holes on the side of the Connect server and
secure to the Connect server chassis using the 6-32 flat head screws.
4.
Repeat for the opposite side of the Connect server.
5.
Use the upper and lower end of the Connect server mounting rack ears to mark the anchor
positions on the wall. Install self-drilling drywall anchors rated for at least 20 lbs with #6 or #8
screws per the anchor manufacturer’s recommendation.
6.
Install the mounting screws through the rack ear holes and into the anchors. Tighten the screws
to secure the Connect server firmly against the wall.