Allworx
®
Connect™ Server Family Installation Guide
866.ALLWORX * +1 585 421 3850
Page 17
www.allworx.com
Version: F Revised: June 21, 2018
Software Upgrade: New Installation
1.
Download the latest version of the Allworx System Software to a PC from the Allworx Partner
Portal.
2.
(if the web admin login page is not already available) Open a browser window and enter the
URL of https://192.168.2.254:8443. The Welcome to Allworx page displays.
3.
Log in to the Allworx server admin page and navigate to
Maintenance
>
Restart.
4.
Check the box for
Restart Allworx Server
and select
Enter Safe Mode after restart.
5.
Click
Restart Now
. A warning banner displays.
6.
Click
Continue
. The server reboots in Safe Mode. The Power button is yellow.
7.
Enter the URL: 192.168.2.254:8080 in the browser and hit enter.
8.
Locate the
Disk Operations
section and click the
Format
button, and then click
OK
at the
confirmation pop-up window.
9.
Locate the
Software Update
section, and then locate step
3. Load an upgrade file
.
10.
Click the
Browse...
button. Use the browser window to locate the latest version of the Allworx
System Software (downloaded in step 1), and then click
Open
>
Load
.
11.
Locate step
4. Activate the Update
, and then click
Update
, when available.
12.
Locate the
Reboot Operations
section and select
Reboot in Normal Mode.
13.
Click
Reboot
. The Allworx server reboots and the web admin login page displays.
14.
Log in to the Allworx System web admin page, and then continue the
Note:
If using an Allworx Connect server from another installation, the steps below clear
all
data and settings
currently stored on the server.
Note:
In the Restart menu, there is an option to
Restore to Factory Defaults
. This option is only for Allworx
Connect servers currently in use that require resetting the Connect server configuration settings. This
option maintains all user data (i.e., Users). See Appendix A
“Restore Factory Defaults” on page 31
which settings are restored to the factory defaults.
To restore the Connect server to the factory defaults, see the Allworx System Software Administrator
Guide.