Connect™ Server Family Installation Guide
Page 10
866.ALLWORX * +1 585 421 3850
www.allworx.com
Version: F Revised: June 21, 2018
To install the Connect server on a tabletop or shelf:
1.
Remove the four rubber feet from the packaging and turn the chassis over.
2.
Remove the paper backing from one rubber foot and place it at a corner on the bottom of the
chassis.
3.
Repeat for the remaining three rubber feet in the remaining three corners of the chassis.
3.2 Rack Mount
The table below indicates a list of all equipment and requirements necessary to rack mount the
Connect server.
To mount the Connect server:
1.
Verify the clearance around the Connect server front and rear panels for the power, network,
and telephony connections.
2.
Align a rack ear on the side of the Connect server so that:
•
the four holes of the rack ear align with the four holes on the side of the Connect server.
•
the perpendicular side of the rack ear faces outward from the front of the Connect server
to mount into the rack.
3.
Secure to the Connect server chassis using four 6-32 flat head screws. Repeat for the opposite
side of the Connect server.
4.
5.
Install the Connect server into the rack using appropriate hardware.
Equipment
Qty
Requirements
Rack
1
1U high rack mount standard 19” rack
Rack Mount Kit
1
Includes:
• Two rack ears
• Eight 6-32 flat head screws