BIBI 850-BL Use and maintenance manual Rev.00
92
6.13 Electrical insulation monitoring device operation test
Check the operation of the device that monitors the electrical insulation of the 220V power supply
(inverter) at the frequencies indicated in the general chart.
If the test is performed with the combustion engine running, the switch (
1
) in the console must be in
the "OUT 220V" position. This enables 220V voltage to be supplied to the socket alongside the console.
Using the special tool, remove the protective casing from the electrical panel (
2
) which holds the
electrical isolation control device (
3
). Find the monitoring device (
3
) and press the push-button installed
on the front of the residual current circuit-breaker (
4
), generally indicated by the word “test”.
This simulates an abnormal situation and automatic voltage release by the device.
2
1
3
4
Summary of Contents for BiBi 850-BL
Page 22: ...BIBI 850 BL Use and maintenance manual Rev 00 21...
Page 38: ...BIBI 850 BL Use and maintenance manual Rev 00 37 22 21 20 23...
Page 39: ...BIBI 850 BL Use and maintenance manual Rev 00 38 View A 24 8 12 16 25...
Page 40: ...BIBI 850 BL Use and maintenance manual Rev 00 39 17 3 2 26...
Page 100: ...BIBI 850 BL Use and maintenance manual Rev 00 99 2...
Page 106: ...BIBI 850 BL Use and maintenance manual Rev 00 105...
Page 107: ...BIBI 850 BL Use and maintenance manual Rev 00 106...
Page 126: ...BIBI 850 BL Use and maintenance manual Rev 00 125 Appendix 4 Hydraulic diagram...
Page 127: ...BIBI 850 BL Use and maintenance manual Rev 00 126 Appendix 5 Circuit diagram...