PAGE
56
ALMAC s.r.l.
ATTENTION!
If the RED led (7) lights up when the machine is switched on, it means that an
active command is already present at start-up (Joystick contact or movement
selector jammed).
Once ignition is completed it is therefore possible to start the motor:
•
Operate selector no. 2 for motor selection
o
High position: AC 110V or AC 220V electric motor (attention: to use
this motor it is necessary to connect the mains power plug);
o
Low position: 48V DC electric motor.