6.2.8.3
Recharging
The batteries are recharged by connecting to the 110V or 220V mains power
supply.
Do not charge the batteries with current valueshigher than those indicated in
the technical specifications and recommended in the instructions, it could cause
dangerous overheating and a drastic reduction in the life of the battery series.
The Lead Crystal batteries must be recharged mainly by enabling both battery
chargers (40A).
The use of the single battery charger must always take place in
cases of extreme necessity and occasionally.
Attention!! Continuously using only one 20A charger will damage the
batteries.
The Lead Crystal batteries can be recharged only with the battery chargers on
board the machine, in case of a different charging system, contact ALMAC
company for authorisation.
NEVER SMOKE, CREATE SPARKS OR FLAMES NEAR BATTERIES AND BATTERY
CHARGERS: EXPLOSION RISK.
6.2.8.4
Battery storage
Recharge the battery at least every three to four months.
In the event of prolonged immobilisation, charge 100% before storage and before
re-use. In all cases, the storage and maintenance recharges must be performed
through the use of the battery chargers on board the machine and both must be
enabled.
Make sure the batteries are stored in areas out of the reach of children.
Summary of Contents for MULTI-LOADER 2.5
Page 41: ...PAGE 41 ALMAC s r l...
Page 67: ...PAGE 67 ALMAC s r l A number of examples follow...
Page 68: ...PAGE 68 ALMAC s r l...
Page 69: ...PAGE 69 ALMAC s r l...
Page 105: ...PAGE 105 ALMAC s r l 8 ATTACHMENTS 8 1 Declaration of conformity FAC SIMILE...
Page 107: ...PAGE 107 ALMAC s r l MANDATORY ROUTINE INSPECTIONS Date Observations Seal Signature...
Page 117: ...PAGE 117 ALMAC s r l 8 4 Hydraulic diagram See attachment 8 5 Wiring diagram See attachment...