Installation & Systems Manual RUBIDIUM SERIES
Page 57
3.22
GT/GI/GL
: Standard Options
You will find detailed information in the operating manuals mentioned below.
All manuals are available Option Description
-V
: VITC generator
for
GT
The VITC generator inserts VITC in an analogue video. The data
content will be identical to the LTC output.
→
Operating manual:
“GT Modules“.
-L
: Time & date
reference via
external LTC
for
GT
/
GL
/
GI
With standard firmware the module accepts a time & date
reference via serial data and a pulse per second (PPS). Using an
external LTC instead requires this option “L”.
→
Operating manual:
“GT/GL/GI Modules Option L“.
-I
: Time & date
reference via
external IRIG-B
for
GT
/
GL
/
GI
With standard firmware the module accepts a time & date
reference via serial data and a pulse per second (PPS). Using an
external IRIG-B instead requires this option “L”.
→
Operating manual:
“GT/GL/GI Modules Option I“.
-M
: Impulse telegram
output to control
analogue clocks
for
GT
/
GL
/
GI
With this option a built-in distribution amplifier supplies the
analogue clocks of the
AlVelte
system with power as well
as with time data. The time data forms a telegram similar to the
German radio time telegram DCF77. The data bits are transmitted
every second except at second = 59. The time data are
synchronous to the internal clock of the module.
→
Operating manual:
“GT/GL/GI Modules Option M“.
-A
: Controlling MTD
timers by an
automation system
for
GT
With this option the module receives timer data via one or more
serial interfaces. These timer data can be assigned to any MTD
timer. The RS485 of the MTD system used for manual controlling
the MTD timer will still be available without constraints. So each
MTD timer now can be controlled manually or automatically.
→
Operating manual:
“GT Modules Option A“.