Installation & Systems Manual RUBIDIUM SERIES
Page 69
3.34
SV
: VITC Monitoring and Changeover Unit
This module can frame accurate and in real-time compare and contrast two incoming VITCs
for indescribable differences. In the event of a failure, “SV” automatically switches to the other
faultless source. The SV module is a must for all time code systems where failure proof VITC is
a requirement. This includes real-time applications. Additionally, it monitors VITC, video and
reference errors, VITC/VITC and VITC/reference differences, and it makes status information
about all sources available.
AlVelte
VITC OUT
VITC IN 1
VITC IN 2
REF OUT
GPI OUT
REF IN
REF OUT
8 . . . . . 1
8 . . . . . 1
1 . . . . . 8
1 . . . . . 8
VITC IN (2 x BNC)
:
Video format
CVBS analogue video signal: PAL 625/50, NTSC 525/60
Signal level
1 V
6 dB at 75
VITC
According to ANSI/SMPTE 12M-1-2008
VITC OUT (BNC)
:
Video/VITC
VITC output, switched via relay to one input
REF IN (RJ45)
:
PPS IN
Pulse per second, input
RXD IN
Reference time & date input, serial data string
REF OUT (2 x RJ45)
:
PPS OUT
Pulse per second output, hard-wired with signal at REF IN
TXD OUT
Reference time & date output, hard-wired with signal at REF IN
GPI OUT (RJ45)
:
FAIL Failure
signals
WARNING Warning
signals
Others
:
Operating voltage
12 - 30 V DC
Power consumption
1.5 W maximum
Weight
0.3 kg approx.
Mechanical
Standard circuit board (W x D): 100 x 160 mm / 3.94 x 6.30 inch
Rear panel: RUB H1: 103 x 44 mm / 4.06 x 1.73 inch
RUB H3: 8HP, 3RU