background image

 

 

 

10

 

 
Table 4- GSM Relay Sensor Alarm Switch Settings 
 

Cell#

 

Cell label

 

Default 

Value

 

Description

 

Available Values 

1sms 

000 

1st telephone 
number (primary) for 
notification 

Enter number in the following format 
+1********** e.g.:+17180000000 

2sms 

000 

Telephone numbers 
for 

notification

 

 

Enter number in the following format 
+1********** e.g.:+17180000000 
 

3sms 

000 

4sms 

000 

5sms 

000 

6sms 

000 

BALANS 

Remaining balance 
Inquiry USSD 
 

 

Auto detection of remaining balance tel. 
number; 
Manual entry of tel.# e.g.: *100# 

14 

TEST 

Frequency for test/ 
status SMS 
notifications 
 

 

 

Sets frequency for test/ status SMS 
notifications. Interval sets up to 250 days. 
e.g.: 
1- Notification once a day 
7- Notification once a week   

 

0- Notification not sent. 

18 

AlarmNot 

Alarm  notification 
Option/Type when 
Relay contact 
position Changes
 

 

0- Only SMS to 
1sms...6sms 
1- Call + SMS 
(SMS sent to1sms, then callsplaced to all 
tel.   numbers, followed by SMS transmittal 
to allremaining tel.numbers @2sms... 6sms. 
3- Only calls placed to 1sms...6sms 

26

*

 

Pcn ON 

Event Description 
whenRelay Contacts 
Closed 

Text up to 20 Latinalphabet characters, 
e.g.: ALARM 
 
 

27

*

 

Pcn OFF 

Event Description 
whenRelay Contacts 
Open   

0- Notification not executed 

34** 

POLUS 

Template name 
w/settings 

35 

Мnum 

000 

For operation 
w/Polus  
GSM Security Panel 
application 

Relay SensorAlarmSwitch SIM Tel.# 
 

 

36 

LANG 

Notification 
Language 

0-Ru 
1-En 

 
*-  

Attention!

In cell’s No.26 and No.27, instead of setting (changing) the value, the cell label name 

should be changed. 

 

 

**- Operating service data that creates template during GSM Alarm Sensor Switch set-up. 
 

Summary of Contents for polus gsm

Page 1: ...3 ...

Page 2: ... 1 5 Operation of the GSM Relay Sensor Alarm Switch 7 2 Set Up 8 2 1 Preparing the GSM Relay Sensor Alarm Switch for operation 8 2 2 Configuring the GSM Relay Sensor Alarm Switch 8 2 3 Accessing Programing mode 10 2 4 Setting up for First Time Use 11 2 5 Verifying set up 11 2 6 Changing Adjusting the Parameters 12 2 7 GSM Relay Sensor Alarm Switch Installation 13 3 Troubleshooting the POLUS GSM Re...

Page 3: ...Programming Armed On Guard POLUS GSM Relay Sensor Alarm Switch FEATURES Installs at any location with mobile GSM reception Arms and Disarms by simply turning power ON or OFF Settings programmable via mobile telephone online and thru utilizing Configurator Express GSM Android iOS apps or the GSM Central Control Monitoring Panel Uses two interface languages English and Russian Operates on a single 3...

Page 4: ...ns do not exceed 109x32x27 5 mm Relay Sensor Alarm Switch w battery weight does not exceed 60 g Note The Relay Sensor Alarm Switch is capable of operating at temperatures below 25 C but the battery operating life will be reduced as well as the number of transmitted SMS notifications 1 4 Relay Sensor Alarm Switch Design The Relay Sensor Alarm Switch unit consists of a cover body with a LED indicato...

Page 5: ...sor Alarm Switch contacts The two color LED s indicate the state of the Relay Sensor Alarm Switch in accordance with table 3 The GSM module circuit board contains a SIM cardholder XS3 and a GSM LED to indicate network signal strength Diagram 3 Exposed view of the controller circuit board and GSM module The Relay Sensor Alarm Switch ships with an installed battery insulated from the battery contact...

Page 6: ...all the settings are completed the Relay Sensor Alarm Switch enters Armed On Guard mode While in Armed On Guard mode and when triggered by inputvia terminal block X2 causing a change in the position of the Relay Switch contacts Opened Closed the Relay Switch will enter ALARM mode and will then execute notifications via SMS and or by placing outgoing calls After concluding ALARM notifications the R...

Page 7: ...ine is busy When the subscriber is out of network Calling out will cease after one of the subscriber numbers picks up and disconnects then the GSM Relay Sensor Alarm Switch will transmit Alarm Diag 4 notifications to the numbers located at cell positions 2SMS 6SMS Diagram 4 Default notification indicating the position of the Relay contacts Pcn ON Relay contacts closed Pcn OFF Relay contacts open S...

Page 8: ...once a week 0 Notification not sent 18 AlarmNot 1 Alarm notification Option Type when Relay contact position Changes 0 Only SMS to 1sms 6sms 1 Call SMS SMS sent to1sms then callsplaced to all tel numbers followed by SMS transmittal to allremaining tel numbers 2sms 6sms 3 Only calls placed to 1sms 6sms 26 Pcn ON 1 Event Description whenRelay Contacts Closed Text up to 20 Latinalphabet characters e ...

Page 9: ...lay Sensor Alarm Switch has entered Programing mode During the entire duration of the Programing mode the LED indicator will glow green In the event the GSM LED continues to flash quickly the SIM card is not registering on the GSM network and might be due to the SIM card being incorrectly or not installed blocked by a PIN code or the GSM network is inaccessible take steps in accordance with table ...

Page 10: ...all is received the GSM Relay Sensor Alarm Switch will transmit an SMS containing the settings see diag 8 to the primary telephone number and will then enter Armed On Guard mode If you were unable to record all the necessary additional notification telephone numbers either re insert in the Protective Plastic Insert between the battery and contacts or remove the battery wait 2 two minutes and then ...

Page 11: ... marks and spaces In order to change several parameters at once it is necessary to list the parameters separating them with a comma For example 2 1xxxxxxxxxx 18 3 27 Alarm 36 1 etc Note Characters are entered without quote marks and spaces 2 Access Programing mode in the GSM Relay Sensor Alarm Switch item 2 3 3 Send a previously prepared SMS message to the GSM Relay Sensor Alarm Switch telephone S...

Page 12: ...cables Diag 7 Installation Size Specifications In order to install the GSM Relay Sensor Alarm Switch consecutively execute the following steps 1 Select a location to install the GSM Relay Sensor Alarm Switch 2 Mark up the selected installation location bearing in mind measurements and the location of mounting holes as located on the GSM Relay Sensor Alarm Switch base 3 Install the GSM Relay Sensor...

Page 13: ...k is inaccessible 1 Verify the presence of a SIM card 2 Remove SIM card re install as shown in diag 7 3 Disable the SIM card PINcode feature by using a GSMTelephone see tel operatingmanual 4 a Re locate the GSM Relay Sensor Alarm Switch to a location with good access to a GSM Network signal in accordance with item 2 7 inthis user s manual b Change the mobile Network provider When verifying operati...

Page 14: ...not in accordance with the instruction manual The warranty does not cover physical damage of any kind whatsoever nor does it cover damage caused by any attempt to tamper with or disassemble the product The warranty coverage does not extend to the batteries The warranty period commences on the day first purchased from the manufacturer or an authorized reseller as evidenced by a purchase receipt Wit...

Page 15: ...17 ...

Reviews: