3
2.1
PERFORMANCE - NATURAL GAS
2
TECHNICAL DATA
Alpha SY24 - Technical Data
Min. Clearances for Servicing
Top
(from casing)
Bottom
Sides
Front
Flue Terminal Size
Flue Terminal Protruding
Hole Size Required For Flue Assy.
Lift Weight
2.4
INSTALLATION
220 mm
250 mm
5 mm
450 mm
100 mm Dia.
130 mm
110 mm Dia.
38 kg
MAX.
28.4
96 900
23.3
79 500
10.7
4.28
2.71
95.70
MIN.
12.1
41 300
9.3
31 700
2.2
0.9
1.16
40.96
Room sealed chamber
panel fitted
Central Heating
Heat Input
kW
(Gross)
Btu/h
Heat Output (modulating)
kW
Btu/h
Burner Pressure
mbar
Settings
in wg
Gas Rate
m³/h
ft³/h
Burner
Main Heat exchanger
Main Burner Injectors
Flue - Outer Duct
Flue - Inner Duct
Stainless steel
Copper
1.30 mm (x12)
White
Aluminium
2.3
COMPONENTS
Central Heating (Sealed System)
Max. Working System Pressure
Min. System Pressure
Max. System temperature
Pressure Relief Valve Setting
Expansion Vessel Size (pre-charge press.)
Flow Connection
Return Connection
Relief Valve Connection
Recommended System Pressure (cold)
CH Water Temp. (Approx. max.)
2.5 bar
0.5 bar
82°C
3 bar (44 PSI)
8 L at 0.8 bar
22 mm
22 mm
15 mm
1.0 bar
82°C (180°F)
2.2
SYSTEM
Summary of Contents for SY24
Page 25: ...25 Alpha SY24 Wiring Diagrams 9 1 ILLUSTRATED WIRING DIAGRAM 9 WIRING DIAGRAMS ...
Page 26: ...26 9 2 FUNCTIONAL FLOW WIRING DIAGRAM Alpha SY24 Wiring Diagrams ...
Page 28: ...28 10 3 FAULT FINDING SOLUTION SECTIONS A to F Alpha SY24 Fault Finding ...
Page 29: ...29 Alpha SY24 Fault Finding 10 4 FAULT FINDING SOLUTION SECTIONS G to J ...