ADM-PCIE-8V3 User Manual
LEDs
Status
Green
Running and no alarms
Green + Red
Standby (Powered off)
Flashing Green + Flashing Red
(together)
Attention - critical alarm active
Flashing Green + Flashing Red
(alternating)
Service Mode
Flashing Green + Red
Attention - alarm active
Red
Missing application firmware or
invalid firmware
Flashing Red
FPGA configuration cleared to
protect board
Table 15 : Status LED Definitions
3.8 SMA Timing Input
All cards are fitted with a U.FL connector that can be utilized as a timing input. This connector can be accessed
with a U.FL cable internal to the chassis, or cabled to an SMA or similar connector at the frton panel. Contact
sales@alpha-data.com for front panel connector options.
Input is on FPGA pin P30, IOSTANDARD LVCMOS18
The signal is isolated through a optical isolator part number ACPL-M61L with a 739 ohm of series resistance.
Figure 11 : Timing Input Schematic
Page 16
Functional Description
ad-ug-1308_v1_9.pdf