EMS Introduction and Set up
Fire-fighting instructions
1. If fire occurs when charging batteries, if it is safe to do so, disconnect the battery pack circuit
breaker to shut off the power to charge.
2. If the battery pack is not on fire yet, extinguish the fire before the battery pack catches fire.
3. If the battery pack is on fire, do not try to extinguish but evacuate people immediately.
There may be a possible explosion when batteries are heated above 150
°
C. When the battery
pack is burning, it leaks poisonous gases. Do not approach.
Effective ways to deal with accidents
Battery in dry environment: Place damaged battery into a segregated place and call local fire
department or service engineer.
Battery in wet environment: Stay out of the water and don’t touch anything if any part of the battery,
inverter, or wiring is submerged.
Do not use a submerged battery again and contact the service engineer.
4.
EMS Introduction and Set up
4.1
Function Description
Figure 54 SMILE5 EMS Interface
Object
Name
Description
A
Indicator LED
Red:
The inverter is in fault.
B
Green:
The battery is in charging or
discharging.
C
Green:
The inverter is in normal state.
D
Green:
The inverter is in communication.
E
Button Function
Return Button: Escape from current
interface or function.
F
Up button: Move cursor to upside or
increase value.