Introduction
900-0184-01-00 Rev A
7
Figure 1
Example of Residence with ICS Plus
Fuses
AFCI
Contactor
PV Array
≤ 10 Feet
Utility
Meter
Combiner
RSI
Battery-Based Inverter
Charge
Controller
Battery
Bank
RTB
BKR-CTRL-DC
Combiner Box
Contains OCPD, AFCI, main contactor, PV Combiner Disconnect
Includes local disconnect to de-energize PV circuits within 10 feet of the array
Rapid Shutdown Initiator (RSI)
Contains control circuit for PVRSS (contactors and relay-trip breakers)
Includes PVRSS disconnect switch
Includes LED indicators for PV connection, disconnection, or arc fault
Relay-Trip Breaker (RTB)
Removes charge controller(s) from PV circuit
Can be integrated into OutBack GSLC or FLEXware enclosures
Circuit Breaker Control Box (BKR-CTRL-DC)
Provides power to combiner, RSI, and RTB
HOUSE EXTERIOR
HOUSE INTERIOR
ROOF