Displays
Alpha IP ETRV 61001
7 Displays
7.1 Status displays
Display
Meaning
Meaning
Operating lock active Deactivate the op-
erating lock via the
app.
Long lighting in
green
Process confirmed
Confirmation of per-
formed setting/trans-
mission.
1 lighting in orange
and 1 lighting in
green (after inserting
the batteries)
Test indication
• Wait until the mo-
tor has retracted
completely.
• Perform an adap-
tation run.
• Wait until the de-
vice is ready.
Short flashing, or-
ange
Radio transmission
Wait until the trans-
mission has ended.
Short flashing, or-
ange (once every 10
seconds)
Teach-in mode active Enter the last four
digits of the serial
number of the de-
vice.
Long/short flashing,
orange (alternately)
Updating the device
software
Wait until the update
is finished.
7.2 Error indications
Display
Meaning
Solution
F1
Valve drive is sluggish Check the valve for
smooth operation.
F2
Setting range is too
large
Check the fixing of
the device.
F3
Setting range is too
small
Check the valve for
smooth operation.