DEU
ENG
24
Commissioning
Alpha IP FSM 26001
5.1.1 Installation in flush-type box
WARNING
Electrical voltage! Danger to life!
¾
Only an authorised electrician may install and connect the device.
¾
Always disconnect from the mains network and secure against unin-
tended activation before assembly and installation.
The wiring of a room-by-room temperature control system depends on
several factors and must be planned and carried through carefully by
the installer.
The following cross-sections are applicable for the plug-in/clamping
connections:
• rigid wire: 0.75 – 1.5 mm²
• flexible wire: 0.75 – 1.5 mm²
• 8 mm insulation stripped off the wire
1. Disconnect from the mains network and secure against unintended
activation.
2. Connect phase (L) and neutral conductor (N) for supply (see figure):
3. Lead the switched phase (1) to the conductor.
4. Insert the Switch Actuator and Meter into a suitable flush-type box.
Remove the fixing lug if necessary.
5. Close the flush-type box with a suitable cover.
6. Connect to the mains network.
9
The teach-in mode is activated for three minutes.(see „Teach-in of the
device“ page 26)