Operating modes and configuration
49
DEU
FRA
ITA
ENG
NDL
ESP
ENG
“Pr.Ad”
for the individual setting of the week profiles („no. 1, no. 2 ... no. 6“). Up
to 6 heating phases (13 switch-over points) can be set in the week profile for every
week day for the selected heating profile. Programming is made for the selected
days for the time from 00:00 to 23:59 o’clock.
1. In the menu item “Pr.Ad”, select the number of the desired profile by turning
the setting wheel (E) and confirm the selection by shortly pressing the wheel.
2. Select the desired week day/working day/weekend/all days by turning the setting
wheel (E) and confirm the selection by shortly pressing the wheel.
3. Confirm the start time of 00:00 o’clock by shortly pressing the setting wheel (E).
4. Select the desired temperature for the starting time by turning/pressing and confirm.
5. Select and confirm the time indicated in the display by turning/pressing the set-
ting wheel.
6. Select the desired temperature for the set period by turning/pressing and confirm.
7. Repeat the process for the complete period from 00:00 to 23:59 o’clock.
Week profile 1-3: Heating, 4-6: Cooling
In case of a CO signal the program changes from heating or cooling auto-
matically according to the following scheme:
1 (heating) to 4 (cooling), 2 (heating) to 5 (cooling), 3 (heating) to 6 (cool-
ing) resp. vice versa.
“OSSF”
serves for activating (“On”) or deactivating (“OFF”) the Smart Start/Stop
function. Once this function is activated, the system calculates in a self-teaching
Summary of Contents for WTHP 61001 Series
Page 1: ...WTHP 61001 XX Alpha IP DEU FRA ITA ENG NDL ESP 133960 1740 ...
Page 3: ...DEU FRA ITA ENG NDL ESP 3 1 A F C D E B ...
Page 4: ...ESP NDL ENG ITA FRA DEU 4 R 3 4 5 S Q P Q P 2 ...
Page 5: ...DEU FRA ITA ENG NDL ESP 5 6 ...
Page 167: ......
Page 168: ...133960 1740 ...